Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/35541
Type: Dissertação
Title: Estudo de comportamento mecânico de uma cortina de estacas atirantada
Other Titles: Study of mechanical behavior of a contiguous piled wall with ground anchor
Authors: Pedro Santana Moreira
First Advisor: Maria das Graças Gardoni Almeida
First Co-advisor: Lúcio Flavio de Souza Villar
First Referee: Enivaldo Minette
Second Referee: Christianne de Lyra Nogueira
Third Referee: Karla Pimentel Maia
Abstract: As contenções em cortina de estacas atirantadas são elementos bastante utilizados em obras de edificações residenciais, construções industriais e mineração, principalmente em função da topografia local e da construção de pavimentos subterrâneos. Em relação às soluções convencionais, tais como cortina atirantada convencional e parede diafragma, a cortina de estacas atirantadas destaca-se pelo baixo custo e prazo de execução. Este trabalho objetivou a retroanálise do comportamento mecânico de um trecho de uma contenção construída com estacas atirantadas através de modelagem numérica. Foram avaliados os parâmetros de resistência do solo e, por meio do método de elementos finitos, em uma análise tensão deformação 2D e 3D, realizou-se a retroanálise com base nos resultados obtidos na instrumentação do inclinômetro. Com isso, os parâmetros de resistência ao cisalhamento foram testados dentro de uma faixa de variação estabelecida por uma análise estatística feita com os resultados dos ensaios de laboratório (compressão triaxial) e de campo (CPTu, DMT, PMT e SPT) executados para o projeto. Na fase inicial da análise numérica 2D foram estudados os limites superior e inferior bem como a média dos resultados dos parâmetros obtidos nos ensaios. Foi possível verificar quais valores de parâmetros de resistência e compressibilidade levaram o modelo a melhor representar as inclinações medidas, e assim, indicar se os ensaios obtiveram parâmetros capazes de reproduzir os deslocamentos horizontais medidos pelos inclinômetros. Foram comparados os esforços da contenção (empuxo, momento e força cisalhante) nas análises numéricas 2D e 3D. Algumas divergências quanto aos modelos foram encontradas, sendo que, os deslocamentos horizontais da contenção na condição 3D, utilizando os mesmos parâmetros da análise 2D, foram menores. Com isso, os empuxos foram maiores na análise 3D, permitindo menores deslocamentos. Foi possível identificar a diferença de 66% no esforço cisalhante quando comparados os resultados da análise numérica 2D e 3D. Com relação ao momento essa diferença foi de 30%.
Abstract: The contiguous piled wall with ground anchor are elements widely used in the construction of residential buildings, industrial buildings and mining, mainly due to the local topography and the construction of underground floors. In relation to conventional solutions, such as conventional anchored wall and diaphragm wall, the contiguous pile wall with ground anchor stands out for its low cost and deadline. This work aimed at the retroanalysis of the mechanical behavior of a sector of a retaining built with piled with ground anchor by numerical modeling. The soil resistance parameters were evaluated and, using the finite element method, in a 2D and 3D stress strain analysis, a retroanalysis was performed based on the results obtained in the inclinometer instrumentation. So, the shear strength parameters were tested within a range established by a statistical analysis made with the results of the laboratory tests (triaxial shear test) and field tests (CPTu, DMT, PMT and SPT) performed for the project. In the initial phase of 2D numerical analysis, the upper and lower limits were studied, as well as the average of the results of the parameters obtained in the tests. It was possible to verify which values of resistance and compressibility parameters led the model to better represent the measured horizontal displacements, indicating if the tests reach parameters capable of reproducing the horizontal displacements measured by the inclinometers. The efforts of the retaining (earth pressure, moment and shear force) in 2D and 3D modeling were compared. Some divergences between models were found, the horizontal displacements of the retaining in the 3D condition, using the same parameters of the 2D analysis, were smaller. Therefore, the earth pressure was greater in the 3D analysis, allowing smaller displacements. It was possible to identify the difference of 66% in shear stress when comparing the results of numerical analysis 2D and 3D. Regarding the moment, this difference was 30%.
Subject: Mecânica do solo
Muros
Método dos elementos finitos
Deformações e tensões
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ENG - DEPARTAMENTO DE ENGENHARIA TRANSPORTES E GEOTECNIA
metadata.dc.publisher.program: Programa de Pós-Graduação em Geotecnia e Transportes
Rights: Acesso Aberto
metadata.dc.rights.uri: http://creativecommons.org/licenses/by/3.0/pt/
URI: http://hdl.handle.net/1843/35541
Issue Date: 29-Jun-2016
Appears in Collections:Dissertações de Mestrado

Files in This Item:
File Description SizeFormat 
Dissertação Pedro Santana Moreira Final (1).pdfDissertação Pedro Santana Moreira17.63 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons