Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/40850
Registro completo de metadatos
Campo DCValorIdioma
dc.creatorNatanny Almeida Santospt_BR
dc.creatorAne Patrícia Caciquept_BR
dc.creatorÉrica Soares Barbosapt_BR
dc.creatorFlaviano Oliveira Silvériopt_BR
dc.creatorGevany Paulino de Pinhopt_BR
dc.date.accessioned2022-04-06T21:51:17Z-
dc.date.available2022-04-06T21:51:17Z-
dc.date.issued2018-
dc.citation.volume97pt_BR
dc.citation.issue14-15pt_BR
dc.citation.spage1393pt_BR
dc.citation.epage1404pt_BR
dc.identifier.doi10.1080/03067319.2018.1424331pt_BR
dc.identifier.issn1029-0397pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/40850-
dc.description.abstractNo presente estudo, a extração sólido-líquido com purificação a baixa temperatura foi validada para a determinação de 16 hidrocarbonetos aromáticos policíclicos de lodo de esgoto por cromatografia gasosa-espectrometria de massa. As recuperações variaram de 70 a 114% para naftaleno, acenaftileno, acenafteno, fluoreno, fenantreno, antraceno, fluoranteno, pireno, benzo[a]antraceno e criseno, enquanto os compostos benzo[b]fluoranteno, benzo[k]fluoranteno, benzo[a] pireno, indeno[1,2,3-cd]pireno, dibenzo[a,h]antraceno e benzo[g,h,i]perileno apresentaram recuperações entre 40 e 70%. O desvio padrão relativo foi inferior a 13% para todos os compostos. Efeito de matriz negativo foi observado nos 10 compostos com menor tempo de retenção na análise cromatográfica e efeito de matriz positivo observado nos demais. Os limites de quantificação foram de 2 a 20 μg kg−1, cerca de 30 vezes menor que o limite máximo de resíduos permitido em lodo pela União Européia. O método validado produziu a quantificação de 11 PAHs em uma amostra de lodo em concentrações variando de 20–2000 μg kg−1.pt_BR
dc.description.resumoIn the present study, the solid–liquid extraction with low temperature purification was validated for the determination of 16 polycyclic aromatic hydrocarbons from sewage sludge by gas chromatography-mass spectrometry. Recoveries ranged 70–114% for naphthalene, acenaphthylene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene and chrysene, while the compounds benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene and benzo[g,h,i]perylene showed recoveries of between 40 and 70%. The relative standard deviation was less than 13% for all of the compounds. Negative matrix effect was observed on the 10 compounds with less retention time in the chromatographic analysis and positive matrix effect noticed on the others. The limits of quantification were from 2 to 20 μg kg−1, about 30 times less than the maximum residue limit allowed in sludge by the European Union. The validated method produced quantification of 11 PAHs in one sludge sample at concentrations ranging 20–2000 μg kg−1.pt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentICA - INSTITUTO DE CIÊNCIAS AGRÁRIASpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofInternational journal of environmental analytical chemistrypt_BR
dc.rightsAcesso Restritopt_BR
dc.subject.otherBiosólidospt_BR
dc.subject.otherPAHspt_BR
dc.subject.otherEfeito de matrizpt_BR
dc.subject.otherSLE-LTPpt_BR
dc.titleValidation of a method for extraction of polycyclic aromatic hydrocarbons from sewage sludge and analysis by GC-MSpt_BR
dc.title.alternativeValidação de um método para extração de hidrocarbonetos aromáticos policíclicos de lodo de esgoto e análise por GC-MSpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.tandfonline.com/doi/full/10.1080/03067319.2018.1424331?needAccess=truept_BR
Aparece en las colecciones:Artigo de Periódico

archivos asociados a este elemento:
no existem archivos asociados a este elemento.


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.