Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/46315
Registro completo de metadatos
Campo DCValorIdioma
dc.creatorReginaldo Gonçalves Leão Juniorpt_BR
dc.creatorRômulo Verdolin de Sousapt_BR
dc.creatorArno Heeren de Oliveirapt_BR
dc.creatorHugo Lemos Leonardo Silvapt_BR
dc.creatorArnaldo Prata Mourãopt_BR
dc.date.accessioned2022-10-18T14:59:01Z-
dc.date.available2022-10-18T14:59:01Z-
dc.date.issued2016-
dc.citation.volume10pt_BR
dc.citation.issue1pt_BR
dc.citation.spage2pt_BR
dc.citation.epage8pt_BR
dc.identifier.doihttps://doi.org/10.29384/rbfm.2016.v10.n1.p2-8pt_BR
dc.identifier.issn1984-9001pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/46315-
dc.description.abstractEste trabalho teve como objetivo principal a obtenção de dados de pequenos campos de raios X que evidenciassem as hipóteses apontadas como dificultadoras para a dosimetria destes. Foi realizadaa verificação da compatibilidade entre o limitedo campo dosimétrico com o campo geométrico e a verificação da relação kerma-dose segundo oesperado paracampos convencionais. Materiais e Métodos: Simulações computacionais de campos menores que 5x5 cm² foram realizadasutilizando o método de Monte Carlopor meioda aplicação egs_chamber, esta derivada do código de transporte de radiação EGSnrc. Como fontesde partículas,foram utilizados phase space filesde um modelo de cabeçote do acelerador linear CLINAC 2100acoplado a cones deRadiocirurgia Estereotáxica. Resultados: As simulações sugeriram a existência de um patamar, próximo de 8%,nas discrepâncias entre o FWHMda Dosee o diâmetro nominal do campo, indicando um decréscimo destes valores para campos de diâmetrosmenoresque 12 mm e maiores que 36mm.Simultaneamente,asdiscrepâncias dose-kerma em profundidade atingiram valoressuperiores a14% no caso onde o fenômeno foi mais significativo. Conclusão: Os dadosda relação kerma-dosemostraram que,de fato,o comportamento dos pequenos campos destoa daquele esperado para campos convencionais, e que as convenções dosimétricas tradicionais não se aplicam a tais campos,sendo necessária uma abordagem especializada para as técnicas que os empregam.Além disto, a existência do já referido patamar de discrepâncias, juntamente com a diminuição destas em campos de diâmetro menor que 15 mm, constituem um achado notável.pt_BR
dc.description.resumoThis work aimed to obtain data from small fields of X-rays that evidence of the hypotheses cited as cause of difficulties for the dosimetry of these. For this purpose, the verification of compatibility between the dosimetric boundary offield and the geometricsize offield, was performed. Also,theverification of kerma dose according to the expected relationship for conventional fieldswas made.Materials and Methods: Computer simulations of smaller fields 5x5 cm² were performed,using the Monte Carlo method by egs_chamber application, this derived from EGSnrc radiation transport code.As particulate sources were used phase spacefilesof a Clinac 2100head modelcoupled to cones Stereotactic Radiosurgery.Results: The simulations suggested the existence of a plateau in discrepancies between thedoseFWHM and the nominal diameter of the fieldclose to 8%. These simulations also indicated a decrease of these values for fields with diameterssmallerthan 12mm and larger than 36mm.Simultaneously, the dose kerma differences in depth reached values higher than 14% in the case where the phenomenon is more significant.Conclusion: The data showed that in fact the behavior of small fields clashes with that expected for conventional fields, and that the traditional dosimetric conventions do not apply to such fields requiring a specialized approach to the techniques that employ them.Furthermore, the existence of the aforementioned plateauofdiscrepancies, along with the decrease thereof in less than 15 mm diameter fields constitute a remarkable finding.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA NUCLEARpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofRevista Brasileira de Física Médicapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectSnall fieldspt_BR
dc.subjectDosimetrypt_BR
dc.subjectMonte Carlopt_BR
dc.subjectEGSnrcpt_BR
dc.subjectPequenos Campospt_BR
dc.subjectDosimetriapt_BR
dc.subject.otherEngenharia nuclearpt_BR
dc.titleComputational analysis of 'Dose/Collision Kerma' relationship and lateral boundary in Stereotatic circular fields using EGSnrc.pt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.rbfm.org.br/rbfm/article/view/355pt_BR
Aparece en las colecciones:Artigo de Periódico

archivos asociados a este elemento:
archivo Descripción TamañoFormato 
Computational analysis of 'DoseCollision Kerma' relationship and - PDFA.pdf499.43 kBAdobe PDFVisualizar/Abrir


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.