Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/56752
Full metadata record
DC FieldValueLanguage
dc.creatorMarcel Bahia Lanzapt_BR
dc.creatorAntônio Eustáquio de Melo Pertencept_BR
dc.creatorAndré G. P. Andradept_BR
dc.creatorGustavo H. Peixotopt_BR
dc.creatorLeonardo Bonato Felixpt_BR
dc.creatorMauro Heleno Chagaspt_BR
dc.date.accessioned2023-07-19T19:15:05Z-
dc.date.available2023-07-19T19:15:05Z-
dc.date.issued2017-11-07-
dc.citation.volume19pt_BR
dc.citation.issue4pt_BR
dc.citation.spage375pt_BR
dc.citation.epage384pt_BR
dc.identifier.doihttps://doi.org/10.1590/1980-0037.2017v19n4p375pt_BR
dc.identifier.issn1980-0037pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/56752-
dc.description.abstractO objetivo deste estudo foi propor um dispositivo mecânico que acoplado a uma cadeira flexora aumente a carga mecânica durante toda a ação excêntrica (ECC) e comparar a atividade muscular durante a utilização do dispositivo proposto. Quinze mulheres fisicamente ativas foram recrutadas e realizaram dois diferentes protocolos (controle e sobrecarga ECC). O protocolo controle foi realizado com ações concêntricas (CON) e ECC com carga iguais (60% de uma repetição máxima), enquanto o protocolo de sobrecarga ECC consistiu em ações ECC com 40% mais de carga do que as ações CON. A ativação muscular dos músculos biceps femoris (BF) e gastrocnemius medialis (GM) foi medida por meio de eletromiografia de superfície. Durante as ações ECC foi observada uma maior ativação do BF durante o protocolo de sobrecarga quando comparado ao protocolo controle (p = 0,032). No entanto, GM não apresentou diferenças na ativação entre os protocolos (p = 0,439). O dispositivo mecânico proposto foi capaz de aumentar a carga durante a ação ECC e, consequentemente, a atividade muscular do BF.pt_BR
dc.description.resumoThe aim of this study was to propose a mechanical device that could increase the mechanical load during the entire eccentric (ECC) action on a knee flexor machine and to compare the muscular activity when the device was used during a testing proto col. Fifteen physically active women were recruited, and they performed two protocols: control and eccentric overload. Control protocol was performed with concentric (CON) and ECC actions with similar load (60% of one repetition maximum) whilst eccentric overload protocol consisted of ECC actions with 40% more load than CON actions. Muscular activation was measured using surface electromyography of the biceps femoris (BF) and the gastrocnemius medialis (GM) muscles. ECC actions presented a higher muscular activation during eccentric overload protocol than control protocol for BF (p = 0.032), but not for the GM (p = 0.439). The mechanical device increased the mechanical load during the ECC muscle action and consequently increased the amplitude of the neural drive to the BF muscle; however, it did not increase the amplitude of the neural drive to the GM muscle.pt_BR
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Geraispt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEEF - DEPARTAMENTO DE ESPORTESpt_BR
dc.publisher.departmentEEFFTO - ESCOLA DE EDUCAÇÃO FISICA, FISIOTERAPIA E TERAPIA OCUPACIONALpt_BR
dc.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofRevista Brasileira Cineantropom Humanopt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectContração muscularpt_BR
dc.subjectEletromiografiapt_BR
dc.subjectTreinamento de resistênciapt_BR
dc.subject.otherContração Muscularpt_BR
dc.subject.otherEletromiografiapt_BR
dc.subject.otherTreinamento de resistênciapt_BR
dc.titleAcute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the loadpt_BR
dc.title.alternativeResposta neuromuscular aguda durante um protocolo de sobrecarga excêntrica usando um dispositivo mecânico para aumentar a cargapt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://periodicos.ufsc.br/index.php/rbcdh/article/view/1980-0037.2017v19n4p375pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1955-8990pt_BR
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.