Title: Avaliação e comparação entre métodos de mensuração de pressão arterial sistólica em gatos hígidos
Authors: Tathiana Mourao dos Anjos
First Advisor: Julio Cesar Cambraia Veado
First Co-advisor: Maria Cristina Nobre e Castro
First Referee: Maria Cristina Nobre e Castro
Second Referee: Roberto Baracat de Araújo
Third Referee: Fernanda Vieira Amorim da Costa
Abstract: Foram avaliados e comparados dois diferentes métodos não invasivos (oscilométrico - Petmap®, Ramsey e doppler vascular - Model 812®, Parks Medical) e um invasivo (cateterização arterial - padrão ouro) de mensuração de pressão arterial sistólica (PAS) em 12 gatos hígidos anestesiados e de mesma idade. Os métodos não invasivos também foram avaliados e comparados entre si em 24 gatos hígidos conscientes de diferentes idades. Os métodos não invasivos diferem estatisticamente entre si, entretanto se correlacionam de maneira alta e positiva. O oscilométrico é estatisticamente igual ao invasivo, enquanto que o doppler difere de ambos. Porém, pela forte correlação positiva do doppler com a pressão invasiva, foi possível criar um fator de correção. Não há aumento da PAS em ambos os métodos não invasivos, entre diferentes grupos de idade. Apesar da diferença significativa entre os mesmos, pela correlação alta e positiva, pode-se afirmar que as mensurações de ambos são confiáveis e comprovam a possibilidade de emprego das duas técnicas na rotina clínica, desde que condições mínimas (padronização do procedimento de mensuração e ambiente clínico adequado) sejam respeitadas. A coerência dos resultados obtidos, avaliada pela comparação entre os métodos estudados, está diretamente relacionada aos cuidados aplicados à metodologia de mensuração, pelo doppler e oscilométrico.
Abstract: Were evaluated and compared two different non-invasive methods (oscillometric - PetMap ®, Ramsey and vascular doppler - Model 812 ®, Parks Medical) and invasive (arterial catheterization - the gold standard) measurement of systolic blood pressure (SBP) in 12 healthy cats anesthetized at the same age. The noninvasive methods were also evaluated and compared in 24 healthy cats aware of different ages. The noninvasive methods differ statistically among themselves, however correlate so high and positive. The oscillometric is statistically equal to invasive whereas doppler differs from both. However, the strong positive correlation with the doppler blood pressure measurement, it was possible to create a correction factor. No increase in SBP in both noninvasive methods among different age groups. Despite the significant difference between them, the high positive correlation, it can be stated that the measurements of both are reliable and demonstrate the possibility of using the two techniques in clinical practice, since minimum (standardization of the measurement procedure and environment appropriate clinical) are respected. The consistency of the results obtained, evaluated by comparing the methods studied, is directly related to the care applied to the measurement methodology, the doppler and oscillometric.
Subject: Gato
language: Português
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/BUOS-97XEZH
Issue Date: 27-Feb-2013
Appears in Collections:Dissertações de Mestrado

Files in This Item:
File Description SizeFormat 
disserta__o_tathiana_mour_o_dos_anjos_pdf.pdf3.91 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.