Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/39266
Tipo: Monografia (especialização)
Título: Tratamento pré-cirúrgico de paciente com fissura palatina pré-forame incisivo unilateral através de engenharia reversa – relato de caso clínico
Título(s) alternativo(s): Pre-surgical treatment of a patient with unilateral preforament cleft palate using reverse engineering – clinical case report
Autor(es): Ana Luiza da Silva Barbosa Ferreira
primer Tutor: Leonardo Foresti Soares de Menezes
primer miembro del tribunal : Elizabeth Maria Bastos Lages
Segundo miembro del tribunal: Soraia Macari
Resumen: Objetivo: relatar um caso clínico com abordagem ortopédica pré-cirúrgica em paciente portador de fissura pré-forame incisivo unilateral esquerda realizada a partir do modelador nasoalveolar (NAM) construído por meio de engenharia reversa (ER). Metodologia: Paciente do sexo masculino, 1 mês de idade, portador de fissura pré-forame unilateral esquerda completa, foi submetido ao tratamento pré-cirúrgico com NAM-ER. Inicialmente foi realizada a moldagem do arco superior, seguida do escaneamento do molde e, a partir deste, criado um modelo digital para realizar o planejamento virtual do caso. Após a aprovação do planejamento foram impressos os modelos que serviram de base para a confecção das placas alveolares. As placas alveolares foram trocadas semanalmente e utilizadas associadas à um componente nasal (elevador nasal) e às fitas adesivas labiais. Para avaliação do sucesso do uso do NAM-ER foram realizadas medidas da largura da fissura (F-F’), da largura da região intercaninos (C-C’) e da largura da região intermolares (M-M’), no tempo inicial (T0), pré-cirúrgico (T1) e pós-cirúrgico (T2). Resultados: A medida F-F’ sofreu uma diminuição total (T0-T2) de 3,18mm, sendo que 1,09mm ocorreu no intervalo de tempo de T0-T1 e 2,09mm de T1-T2. As distâncias C-C’ e M-M’ apresentaram um aumento dos seus comprimentos em todos os tempos medidos. C-C’ apresentou um aumento de 3,48mm total (T0-T2), sendo que 2,41mm no intervado entre T0-T1 e 1,07mm no intervalo de T1-T2. Já M-M’ teve um aumento total(T0-T2) de 4,56mm, sendo 4,38mm no intervalo de T0-T1e 0,18mm no intervalo de T1-T2. Conclusão: O NAM construído a partir da engenharia reversa utilizado juntamente com o elevador nasal e as fitas adesivas no lábio mostrou-se efetivo na modelagem nasoalveolar, evidenciando uma diminuição na largura da fissura com melhor conformação dos segmentos alveolares. Com a ER foi possível diminuir a quantidade de consultas e diminuir o tempo clínico de cada atendimento.
Abstract: Objective: to report a clinical case of pre-surgical orthopedic treatment in a patient with pre-foramen unilateral cleft palate performed from the nasal-alveolar molding (NAM) constructed through reverse engineering (RE).Method: a 1-month-old male patient with complete unilateral cleft lip and palate on the left side was submitted to preoperative NAM-RE treatment. Initially the upper arch molding was carried out, followed by the scanning of the mold and, from this, a digital model was created to carry out the virtual planning of the case. After approval of the planning, the models that served as the basis for the preparation of the alveolar plates were printed. The alveolar plates were changed weekly and used associated with a nasal component and lip adhesive. In order to evaluate the success of NAM-RE, measurements of the width of the gap (F-F '), the width of the intercanine region (C-C') and the width of the intermolar region (M-M) in the initial moment (T0), pre-surgical (T1) and postoperative (T2).Results: the F-F 'measure had a total decrease (T0-T2) of 3.18 mm, with 1.09 mm occurring in the time interval of T0-T1 and 2.09 mm in T1-T2. The distances C-C' and M-M' showed an increase in their lengths at all times measured. C-C' showed a total increase of 3.48mm (T0-T2), with 2.41mm in the interval between T0-T1 and 1.07mm in the T1-T2 interval. The distance M-M' had a total increase (T0-T2) of 4.56mm, being 4.38mm in the interval of T0-T1e and 0.18mm in the interval of T1-T2.Conclusion: the NAM constructed from reverse engineering proved to be effective in nasoalveolar modeling, evidencing a decrease in the width of the fissure with better conformation of the alveolar segments. With ER, it was possible to reduce the number of visits and decrease the clinical time of each care.
Asunto: Fenda labial
Fissura palatina
Procedimentos cirúrgicos bucais
Materiais para moldagem odontológica
Idioma: por
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Departamento: FAO - DEPARTAMENTO DE ODONTOPEDIATRIA E ORTODONTIA
Curso: Programa de Pós-Graduação em Odontologia
Tipo de acceso: Acesso Aberto
URI: http://hdl.handle.net/1843/39266
Fecha del documento: 11-dic-2018
Aparece en las colecciones:Especialização em Ortodontia

archivos asociados a este elemento:
archivo Descripción TamañoFormato 
TCC Finalizado Corrigido - após revisão da biblioteca 2 - Ficha catalográfica e ata PDF.pdfTrabalho de Conclusão de Curso1.99 MBAdobe PDFVisualizar/Abrir


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.