dc.description.abstractA avaliação da exposição às partículas com base na dose depositada nos pulmões seria o padrão-ouro para a avaliação de quaisquer efeitos à saúde resultantes. A medição de partículas no condensado da respiração exalada (EBC) – uma matriz contendo água e fluido de revestimento das vias aéreas – pode ajudar a avaliar a retenção de partículas nos pulmões. Este estudo teve como objetivo (1) validar um método de análise de rastreamento de nanopartículas (NTA) para determinar a concentração do número de partículas e sua distribuição de tamanho hidrodinâmico no EBC, e (2) aplicar esse método ao EBC coletado de trabalhadores expostos à pedra-sabão (n = 55) ou pó de quartzo (n=12) e controles (n=11). Uma solução padrão de pérolas de látex foi usada para determinar a faixa linear, limite de detecção (LOD), repetibilidade (coeficiente de variação, CV) e viés em EBC incrementado. Um instrumento LM10 NanoSight com software NTA versão 3.1 foi usado para medição. RTubes® foram utilizados para coleta de campo de EBC. A repetibilidade obtida para a distribuição de tamanho aD50 em EBC apresentou variabilidade menor que 8%, com viés <7%. A concentração de partículas foi linear na faixa de 2,5×108 partículas ml−1 com aLOD de 4×106 partículas ml−1. Uma recuperação de 117±20% a 6,2×107 partículas ml−1 foi obtida com aCV<10% e um viés <20%. O EBC dos trabalhadores expostos ao quartzo, que experimentaram a maior exposição às partículas de sílica, exibiu consistentemente uma concentração estatisticamente significativa (p<0,01) maior de partículas em seu EBC, com uma mudança de distribuição de tamanho para valores maiores do que os outros grupos. Os resultados mostraram que a técnica NTA teve bom desempenho para caracterizar a distribuição de tamanhos e concentrações de partículas em EBC. A técnica precisa ser corroborada com uma população maior de trabalhadores.pt_BR
dc.description.resumoAparticle exposure assessment based on the dose deposited in the lungs would be the gold standard for the evaluation of any resulting health effects. Measuring particles in exhaled breath condensate (EBC)—a matrix containing water and airway lining fluid—could help to evaluate particle retention in the lungs. This study aimed to (1) validate a nanoparticle tracking analysis (NTA) method for determining the particle number concentration and their hydrodynamic size distribution in EBC, and (2) apply this method to EBC collected from workers exposed to soapstone (n=55) or quartz dust (n=12) and controls (n=11). A standard latex bead solution was used to determine the linear range, limit of detection (LOD), repeatability (coefficient of variation,CV), and bias in spiked EBC. An LM10 NanoSight instrument withNTAversion 3.1 software was used for measurement. RTubes® were used for field collection of EBC. The repeatability obtained for aD50 size distribution in EBC showed less than8%variability, with a bias<7%. The particle concentration was linear in the range 2.5×108 particles ml−1 with aLODof 4×106 particles ml−1. A recovery of 117±20% at 6.2×107 particles ml−1 was obtained with aCV<10% and a bias<20%. EBC from workers exposed to quartz, who experienced the largest exposure to silica particles, consistently exhibited a statistically significant (p<0.01) higher concentration of particles in their EBC, with a size distribution shift towards larger values than the other groups. Results showed that theNTAtechnique performed well for characterizing the size distribution and concentrations of particles in EBC. The technique needs to be corroborated with a larger population of workers.pt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentMEDICINA - FACULDADE DE MEDICINApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofJournal of breath researchpt_BR
dc.rightsAcesso Restritopt_BR
dc.subject.otherRastreamento de nanopartículaspt_BR
dc.subject.otherNanopartículas pulmonarespt_BR
dc.subject.otherExposição ocupacionalpt_BR
dc.titleMethod validation of nanoparticle tracking analysis to measure pulmonary nanoparticle content: the size distribution in exhaled breath condensate depends on occupational exposurept_BR
dc.title.alternativeValidação do método de análise de rastreamento de nanopartículas para medir o conteúdo de nanopartículas pulmonares: a distribuição de tamanho no condensado da respiração exalada depende da exposição ocupacionalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://iopscience.iop.org/article/10.1088/1752-7163/aa56ddpt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.