Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/40019
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Luciana Ribeiro Sampaio | pt_BR |
dc.creator | Marcos Antonio de Resende | pt_BR |
dc.creator | Leani Souza Maxima Pereira | pt_BR |
dc.date.accessioned | 2022-03-11T18:52:00Z | - |
dc.date.available | 2022-03-11T18:52:00Z | - |
dc.date.issued | 2016 | - |
dc.citation.volume | 17 | pt_BR |
dc.citation.issue | 2 | pt_BR |
dc.citation.spage | 81 | pt_BR |
dc.citation.epage | 87 | pt_BR |
dc.identifier.doi | https://doi.org/10.5935/1806-0013.20160020 | pt_BR |
dc.identifier.issn | 1806-0013 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/1843/40019 | - |
dc.description.abstract | JUSTIFICATIVA E OBJETIVOS: Avaliar a eficácia analgésica da estimulação elétrica nervosa transcutânea em dor óssea metastática vertebral de pacientes com câncer de mama e sua impacto no consumo de analgésicos. MÉTODOS: Um desenho experimental de caso único foi usado onde foram selecionadas três mulheres com idade entre 40 e 60 anos. O projeto foi A1-B-A2-C-A3-D-A4, onde na fase A os participantes não receberam intervenção, na fase B receberam estimulação elétrica nervosa transcutânea de alta frequência, na fase C estimulação elétrica nervosa transcutânea de baixa frequência e na fase D, a estimulação elétrica nervosa transcutânea virou desligado – placebo. Cada fase inicial durou 7 dias (A: sem intervenção) e as fases B, C e D duraram 10 dias (com intervenção). O consumo de analgésicos e a dor foram avaliados com a visão escala analógica. Os dados foram analisados com o teste de Mann-Whitney para comparar o consumo de analgésicos. Para a análise da escala analógica visual, foram utilizados os testes de linha média dividida e binomial para verificar a diferença entre as fases de linha de base e intervenção, considerando significativo p<0,05. RESULTADOS: Houve consumo significativo de analgésicos diminuição em 66,6% dos voluntários após estimulação elétrica nervosa transcutânea de alta frequência e em 33,3% após estimulação elétrica nervosa transcutânea de baixa frequência. A intensidade da dor pela escala analógica visual foi diminuída em 100% dos voluntários que receberam estimulação elétrica nervosa transcutânea de baixa frequência, em 33,3% daqueles que receberam estimulação elétrica nervosa transcutânea de alta frequência e em 33,3% daqueles que receberam estimulação elétrica nervosa transcutânea desligada (placebo), entre as intervenções e suas respectivas linhas de base anteriores. Em 66,6% dos participantes houve diferença significativa da estimulação elétrica nervosa transcutânea de alta frequência em comparação com suas linhas de base posteriores, bem como em 33,3% quando comparando estimulação elétrica nervosa transcutânea desligada (placebo) e sua respectiva linha de base posterior. CONCLUSÃO: Os resultados sugerem que a estimulação elétrica nervosa transcutânea de alta e baixa frequência pode contribuir como adjuvante no controle da dor óssea vertebral metastática e diminuição do consumo de analgésicos em pacientes com câncer de mama | pt_BR |
dc.description.resumo | BACKGROUND AND OBJECTIVES: To evaluate the analgesic efficacy of transcutaneous electrical nerve stimulation on vertebral metastatic bone pain of breast cancer patients and its impact on analgesic consumption. METHODS: A single case experimental design was used where three females aged between 40 and 60 years were selected. Design was A1-B-A2-C-A3-D-A4, where in phase A participants received no intervention, in phase B they received high frequency transcutaneous electrical nerve stimulation, in phase C low frequency transcutaneous electrical nerve stimulation and in phase D, transcutaneous electrical nerve stimulation turned off – placebo. Each baseline phase lasted 7 days (A: no intervention) and phases B, C and D lasted 10 days (with intervention). Analgesic consumption and pain were evaluated with the visual analog scale. Data were analyzed with Mann-Whitney test to compare analgesic consumption. For visual analog scale analysis, split-middle line and binomial tests were used to verify difference between baseline and intervention phases, considering significant p<0.05. RESULTS: There has been significant analgesic consumption decrease in 66.6% of volunteers after high frequency transcutaneous electrical nerve stimulation and in 33.3% after low frequency transcutaneous electrical nerve stimulation. Pain intensity by the visual analog scale was decreased in 100% of volunteers receiving low frequency transcutaneous electrical nerve stimulation, in 33.3% of those receiving high frequency transcutaneous electrical nerve stimulation and in 33.3% of those receiving transcutaneous electrical nerve stimulation turned off (placebo), between interventions and their respective previous baselines. In 66.6% of participants there has been significant difference of high frequency transcutaneous electrical nerve stimulation compared to their posterior baselines, as well as in 33.3% when comparing transcutaneous electrical nerve stimulation turned off (placebo) and their respective posterior baseline. CONCLUSION: Results suggest that both high and low frequency transcutaneous electrical nerve stimulations may contribute as adjuvant in controlling metastatic vertebral bone pain and decreasing analgesic consumption in breast cancer patients | pt_BR |
dc.format.mimetype | pt_BR | |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | EEF - DEPARTAMENTO DE FISIOTERAPIA | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Revista dor | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Metastasis | pt_BR |
dc.subject | Pain | pt_BR |
dc.subject | Breast cancer | pt_BR |
dc.subject | Electrical therapy | pt_BR |
dc.subject | TENS | pt_BR |
dc.subject.other | Câncer de mama | pt_BR |
dc.subject.other | Estimulação elétrica nervosa transcutânea alta e baixa frequência | pt_BR |
dc.subject.other | Metástase | pt_BR |
dc.title | Effect of transcutaneous electrical nerve stimulation on vertebral metastatic bone pain of breast cancer patients: single case experimental study | pt_BR |
dc.title.alternative | Efeito da estimulação elétrica nervosa transcutânea na dor óssea metastática vertebral de pacientes com câncer de mama: estudo experimental de caso único | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://www.scielo.br/j/rdor/a/RMDmPC3VQSvhh9FHtwYcNyp/?lang=en#:~:text=CONCLUSION%3A,consumption%20in%20breast%20cancer%20patients. | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2016_Effect of transcutaneous electrical nerve stimulation on vertebral metastatic bone pain of breast cancer patients- single case experimental study.pdf | 464.98 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.