dc.description.abstractJUSTIFICATIVA E OBJETIVOS: Avaliar a eficácia analgésica da estimulação elétrica nervosa transcutânea em dor óssea metastática vertebral de pacientes com câncer de mama e sua impacto no consumo de analgésicos. MÉTODOS: Um desenho experimental de caso único foi usado onde foram selecionadas três mulheres com idade entre 40 e 60 anos. O projeto foi A1-B-A2-C-A3-D-A4, onde na fase A os participantes não receberam intervenção, na fase B receberam estimulação elétrica nervosa transcutânea de alta frequência, na fase C estimulação elétrica nervosa transcutânea de baixa frequência e na fase D, a estimulação elétrica nervosa transcutânea virou desligado – placebo. Cada fase inicial durou 7 dias (A: sem intervenção) e as fases B, C e D duraram 10 dias (com intervenção). O consumo de analgésicos e a dor foram avaliados com a visão escala analógica. Os dados foram analisados ​​com o teste de Mann-Whitney para comparar o consumo de analgésicos. Para a análise da escala analógica visual, foram utilizados os testes de linha média dividida e binomial para verificar a diferença entre as fases de linha de base e intervenção, considerando significativo p<0,05. RESULTADOS: Houve consumo significativo de analgésicos diminuição em 66,6% dos voluntários após estimulação elétrica nervosa transcutânea de alta frequência e em 33,3% após estimulação elétrica nervosa transcutânea de baixa frequência. A intensidade da dor pela escala analógica visual foi diminuída em 100% dos voluntários que receberam estimulação elétrica nervosa transcutânea de baixa frequência, em 33,3% daqueles que receberam estimulação elétrica nervosa transcutânea de alta frequência e em 33,3% daqueles que receberam estimulação elétrica nervosa transcutânea desligada (placebo), entre as intervenções e suas respectivas linhas de base anteriores. Em 66,6% dos participantes houve diferença significativa da estimulação elétrica nervosa transcutânea de alta frequência em comparação com suas linhas de base posteriores, bem como em 33,3% quando comparando estimulação elétrica nervosa transcutânea desligada (placebo) e sua respectiva linha de base posterior. CONCLUSÃO: Os resultados sugerem que a estimulação elétrica nervosa transcutânea de alta e baixa frequência pode contribuir como adjuvante no controle da dor óssea vertebral metastática e diminuição do consumo de analgésicos em pacientes com câncer de mamapt_BR
dc.description.resumoBACKGROUND AND OBJECTIVES: To evaluate the analgesic efficacy of transcutaneous electrical nerve stimulation on vertebral metastatic bone pain of breast cancer patients and its impact on analgesic consumption. METHODS: A single case experimental design was used where three females aged between 40 and 60 years were selected. Design was A1-B-A2-C-A3-D-A4, where in phase A participants received no intervention, in phase B they received high frequency transcutaneous electrical nerve stimulation, in phase C low frequency transcutaneous electrical nerve stimulation and in phase D, transcutaneous electrical nerve stimulation turned off – placebo. Each baseline phase lasted 7 days (A: no intervention) and phases B, C and D lasted 10 days (with intervention). Analgesic consumption and pain were evaluated with the visual analog scale. Data were analyzed with Mann-Whitney test to compare analgesic consumption. For visual analog scale analysis, split-middle line and binomial tests were used to verify difference between baseline and intervention phases, considering significant p<0.05. RESULTS: There has been significant analgesic consumption decrease in 66.6% of volunteers after high frequency transcutaneous electrical nerve stimulation and in 33.3% after low frequency transcutaneous electrical nerve stimulation. Pain intensity by the visual analog scale was decreased in 100% of volunteers receiving low frequency transcutaneous electrical nerve stimulation, in 33.3% of those receiving high frequency transcutaneous electrical nerve stimulation and in 33.3% of those receiving transcutaneous electrical nerve stimulation turned off (placebo), between interventions and their respective previous baselines. In 66.6% of participants there has been significant difference of high frequency transcutaneous electrical nerve stimulation compared to their posterior baselines, as well as in 33.3% when comparing transcutaneous electrical nerve stimulation turned off (placebo) and their respective posterior baseline. CONCLUSION: Results suggest that both high and low frequency transcutaneous electrical nerve stimulations may contribute as adjuvant in controlling metastatic vertebral bone pain and decreasing analgesic consumption in breast cancer patientspt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEEF - DEPARTAMENTO DE FISIOTERAPIApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofRevista dorpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectMetastasispt_BR
dc.subjectPainpt_BR
dc.subjectBreast cancerpt_BR
dc.subjectElectrical therapypt_BR
dc.subjectTENSpt_BR
dc.subject.otherCâncer de mamapt_BR
dc.subject.otherEstimulação elétrica nervosa transcutânea alta e baixa frequênciapt_BR
dc.subject.otherMetástasept_BR
dc.titleEffect of transcutaneous electrical nerve stimulation on vertebral metastatic bone pain of breast cancer patients: single case experimental studypt_BR
dc.title.alternativeEfeito da estimulação elétrica nervosa transcutânea na dor óssea metastática vertebral de pacientes com câncer de mama: estudo experimental de caso únicopt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.scielo.br/j/rdor/a/RMDmPC3VQSvhh9FHtwYcNyp/?lang=en#:~:text=CONCLUSION%3A,consumption%20in%20breast%20cancer%20patients.pt_BR