dc.description.abstractCom o crescente uso de técnicas de reconstrução 3D, para auxiliar no diagnóstico, programas dedicados estão sendo amplamente utilizado. Para isso devem ser calibrados de forma a encontrar os valores dos volumes reais do corpo humano tecidos. O objetivo deste trabalho é indicar valores de correção e calibração para volumes verdadeiros, lidos em um 3D sistema de reconstrução dedicado, utilizando imagens DICOM de Tomografia Computadorizada. Este trabalho utilizou um PMMA fantasma de tórax associado à imagem DICOM e o volume encontrado por um programa de tomógrafo. O o volume físico do fantoma de PMMA encontrado foi de 10359,0 cm³. Para os volumes encontrados de acordo com a estruturas de interesse, os valores são 11005,5 cm³, 10249,3 cm³ e 10205,1 cm³ e os valores de correção são -6,2%, +1,1% e +1,5% respectivamente para tecidos: pulmonar, ósseo e tecidos moles. O procedimento realizado pode ser utilizado para calibração em outros programas de reconstrução 3D, observando as correções necessárias e a metodologia utilizada.pt_BR
dc.description.resumoWith the increasing use of 3D reconstruction techniques, to assist in diagnosis, dedicated programs are being widely used. For this they must be calibrated in order to encounter the values of the real volumes of the human tissues. The purpose of this work is to indicate correction and calibration values for true volumes, read in a 3D reconstruction system dedicated, using DICOM images of Computed Tomography. This work utilized a PMMA thorax phantom associated with the DICOM image and the volume found by a program of a tomograph. The physical volume of the PMMA phantom found was 10359.0 cm³. For the volumes found according to the structures of interest, the values are 11005.5 cm³, 10249.3 cm³ and 10205.1 cm³ and the correction values are -6.2%, +1.1% e +1.5% respectively for tissues: pulmonary, bony and soft tissues. The procedure performed can be used for calibration in other 3D reconstruction programs, observing the necessary corrections and the methodology used.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentMED - DEPARTAMENTO DE ANATOMIA E IMAGEMpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofInternational Nuclear Atlantic Conference - INACpt_BR
dc.rightsAcesso Abertopt_BR
dc.subject.otherReconstrução 3Dpt_BR
dc.subject.otherCalibraçãopt_BR
dc.titleCalibration of a dedicated software for 3d renderingpt_BR
dc.title.alternativeCalibração de um software dedicado para renderização 3Dpt_BR
dc.typeArtigo de Eventopt_BR
dc.url.externawww.iaea.org/inis/collection/NCLCollectionStore/_Public/48/094/48094751.pdf?r=1pt_BR