Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/40907
Type: Artigo de Periódico
Title: Influence of biomaterials on scintigraphic diagnosis of periprosthetic infections. Ceftizoxime-99m technetium model
Authors: Luiz Eduardo Moreira Teixeira
Bruno Jannotti Pádua
André Moreira Castilho
Ivana Duval de Araújo
Marco Antônio Percope de Andrade
Valbert Nascimento Cardoso
Simone Odília Antunes Fernandes
Jefferson Soares Leal
Isabella Kuniko Takenaka
Abstract: Purpose: To compare the influence of two metallic implants in the diagnosis of periprosthetic infection using 99m technetium-labeled ceftizoxime. Methods: Twenty rats were randomly divided into four groups, which received sterile and contaminated titanium and stainless steel implants. After 3 weeks, scintilographic images were obtained using a gamma chamber. Radioactivity counts were obtained for the region of interest (ROI) on the operated and non-operated paws. Results: Groups A, B, and C showed homogenous distribution of the radiopharmaceutical. Hyper uptake was observed in the operated paw from group D. The ROI target count was higher in the two groups with stainless steel implants. Among the control groups, the count was higher in the stainless steel group. Furthermore, among the contaminated groups, the uptake was higher in the stainless steel group, with a significant difference. The target: non-target ratio was significantly lower in the control and contaminated groups with both titanium and stainless steel, but the comparison between control groups and contaminated groups was only significant in the former. The cpm/g observed after a decay of 48h showed statistically significant differences between groups. Conclusion: Different biomaterials used in implants have an influence on the results of scintigraphy with 99mTc-CFT.
Subject: Biomateriais
Infecções periprotéticas
Ceftizoxima-99m
language: eng
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: FAR - DEPARTAMENTO DE ALIMENTOS
FAR - DEPARTAMENTO DE ANÁLISES CLÍNICAS E TOXICOLÓGICAS
MED - DEPARTAMENTO DE APARELHO LOCOMOTOR
MED - DEPARTAMENTO DE CIRURGIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: 10.1590/s0102-865020180010000002
URI: http://hdl.handle.net/1843/40907
Issue Date: Jan-2018
metadata.dc.url.externa: https://www.scielo.br/j/acb/a/R4FJhBs5vHXdHPLVhk3TYrf/?lang=en#
metadata.dc.relation.ispartof: Acta Cirúrgica Brasileira
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.