Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/43080
Tipo: Artigo de Periódico
Título: Validity of the accelerometer and smartphone application in estimating energy expenditure in individuals with chronic stroke
Autor(es): Giselle Silva e Faria
Janaíne Cunha Polese
Giane Amorim Ribeiro Samora
Aline Alvim Scianni
Christina Danielli Coelho de Morais Faria
Luci Fuscaldi Teixeira Salmela
Resumo: Objective: To examine the concurrent validity of the GT3X® ActiGraph accelerometer and Google Fit® smartphone application in estimating energy expenditure in people who had suffered a stroke, during fast overground walking. Methods: Thirty community-dwelling stroke individuals walked on a 10-meter hallway over 5 min at their fastest speeds, wearing a Cortex Metamax 3B® ergoespirometer, a GT3X® ActiGraph accelerometer, and a smartphone with the Google Fit® application. Pearson correlation coefficients were calculated to verify the associations between measures of energy expenditure, in kilocalories (kcal), estimated by both devices and those obtained with the Cortex Metamax 3B® ergoespirometer (gold-standard measure). Results: Fair association was found between the energy expenditure values estimated from the combined formula of the ActiGraph GT3X® and those obtained with the gold-standard measure (r = 0.37; p = 0.04). No significant associations were found between the energy expenditure values estimated by the Google Fit® application and those provided by the gold-standard measure. Conclusions: The findings demonstrated that both the GT3X®ActiGraph accelerometer and the Google Fit® smartphone application do not provide valid measures of energy expenditure in chronic stroke individuals during fast overground walking.
Assunto: Acidente vascular cerebral
Energia - Consumo
Monitoramento
Acelerometria
Smartphone
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: EEF - DEPARTAMENTO DE FISIOTERAPIA
Tipo de Acesso: Acesso Restrito
Identificador DOI: https://doi.org/10.1016/j.bjpt.2018.08.003
URI: http://hdl.handle.net/1843/43080
Data do documento: Mai-2019
metadata.dc.url.externa: https://www.sciencedirect.com/science/article/pii/S1413355518300078?via%3Dihub#!
metadata.dc.relation.ispartof: Brazilian Journal of Physical Therapy
Aparece nas coleções:Artigo de Periódico

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.