Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/44671
Full metadata record
DC FieldValueLanguage
dc.creatorCaroline Christine Santa-Rosa,pt_BR
dc.creatorPedro Damas Resendept_BR
dc.creatorIsabella Faria da Cunha Peixotopt_BR
dc.creatorVicente Tadeu Lopes Buonopt_BR
dc.creatorAna Cecília Diniz Vianapt_BR
dc.creatorMaria Guiomar Azevedo Bahiapt_BR
dc.date.accessioned2022-08-29T17:28:53Z-
dc.date.available2022-08-29T17:28:53Z-
dc.date.issued2018-12-23-
dc.citation.volume54pt_BR
dc.citation.spage01pt_BR
dc.citation.epage08pt_BR
dc.identifier.issn21781990pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/44671-
dc.description.abstractObjetivo: Este estudo testa uma configuração para análise experimental in vitro de forças axiais e torque durante o preparo de canais artificiais usando instrumentos endodônticos reciprocantes de níquel-titânio. Métodos: Foi avaliada a eficiência de corte dos instrumentos reciprocantes tamanho 25 / 0,08 (n = 10) Reciproc (RC) e WaveOne (WO), levando em consideração suas características dimensionais e geométricas. Medidas do diâmetro a cada milímetro a partir da ponta, comprimento de pitch, ângulo helicoidal e desenho da área transversal e área foram avaliados. Testes de eficiência de corte foram realizados em um dispositivo de bancada específico, medindo-se o torque e a força axial exigidos durante a modelagem de canais artificiais. A análise estatística foi feita com ANOVA one-way (α = 0,05). Resultados: As amostras de WO mostraram valores médios A3 maiores do que os instrumentos RC (p <0,0001), apesar de terem diâmetros iguais a 3 mm da ponta (D3) (p = 0,521). Os valores médios do comprimento do pitch foram maiores para o RC do que para os instrumentos do WO (p < 0,0001), com consequentemente menores ângulos helicoidais (p < 0,0001). Para os testes de eficiência de corte, o torque necessário foi menor para o grupo RC em comparação com o grupo WO, mas significativo apenas no primeiro estágio de inserção nos canais artificiais (p = 0,008). Em relação à força apical, os instrumentos RC alcançaram valores maiores em relação aos instrumentos WO (p = 0,04) no segundo estágio de corte. Conclusão: Os instrumentos Reciproc demonstraram uma eficiência de corte estatisticamente superior em comparação com os instrumentos WaveOnept_BR
dc.description.resumoAim: This study tested a setup for in vitro experimental analysis of axial forces and torque during the preparation of artificial canals using nickel-titanium reciprocating endodontic files.Methods: The cutting efficiency of Reciproc (RC) and WaveOne (WO) reciprocating size 25/.08 instruments (n = 10) was evaluated, taking into account their dimensional and geometrical features. Measurements of the diameter at each millimeter from the tip, pitch length, helical angle, and cross-sectional design and area were assessed. Cutting efficiency tests were carried out on a specific bench device by measuring the torque and axial force required during artificial canal shaping. Statistical analysis was performed using one-way ANOVA (α = 0.05). Results:The WO samples showed larger A3 mean values than did the RC instruments (p < 0.0001), despite having equal diameters at 3mm from the tip (D3) (p = 0.521). The mean values of pitch length were higher for RC than for WO instruments (p< 0.0001), with consequently smaller helical angles (p < 0.0001). For the cutting efficiency tests, the required torque was lower for the RC group when compared to the WO group, but it was significant only in the first stage of insertion in the artificial canals (p = 0.008). Regarding the apical force, the RC instruments reached higher values when compared to the WO instruments (p = 0.04) in the second stage of cutting action. Conclusion: Reciproc instruments demonstrated statistically higher cutting efficiency when compared to WaveOne instrumentspt_BR
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológicopt_BR
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Geraispt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentFAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofArquivos em odontologia (ufmg)pt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCutting efficiencypt_BR
dc.subjectM-wirept_BR
dc.subjectReciprocating motionpt_BR
dc.subjectReciprocpt_BR
dc.subjectWaveonept_BR
dc.subject.otherCourtshippt_BR
dc.subject.otherEndodonticspt_BR
dc.titleEvaluating the cutting efficiency of niti instruments with reciprocating motionspt_BR
dc.title.alternativeAvaliação da eficiência de corte de instrumentos NiTi com movimento reciprocantept_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://periodicos.ufmg.br/index.php/arquivosemodontologia/article/view/3776pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Evaluating the cutting efficiency of niti instruments with reciprocating motions.pdf585.38 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.