Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/46803
Type: Artigo de Periódico
Title: Influência da estratégia adesiva sobre a sensibilidade pós-operatória em pacientes com restaurações de resina composta à base de silorano
Other Titles: Influence of the adhesive strategy on the post-operative sensitivity in patients with silorane-based resin-composite restorations
Authors: Fabíola Belkiss Santos de Oliveira
Isabela Pereira Marques
João Gabriel Silva Souza
Kaio Henrique Soares
Cláudia Silami de Magalhães
Raquel Conceição Ferreira
Fabiana Mantovani Gomes França
Daniela Araújo Veloso Popoff
Abstract: Objetivo: este estudo avaliou o desempenho clínico de restaurações de resina composta à base de silorano, confeccionadas sob diferentes protocolos de adesão, em relação à presença de sensibilidade pós-operatória. Metodologia: ensaio clínico controlado e randomizado, realizado com 26 pacientes recrutados em uma clínica-escola odontológica. Cada restauração foi confeccionada seguindo um de três protocolos de adesão: G1 (controle 1) tratamento de superfície com sistema adesivo autocondicionante Adper SE Plus 3M/ESPE + Filtek P60® 3M/ESPE; G2 (controle 2) tratamento de superfície com sistema adesivo autocondicionante P90 3M/ESPE + Filtek P90® 3M/ESPE; G3 (teste) tratamento de superfície com ácido fosfórico a 37% + Sistema adesivo P90 3M /ESPE + Filtek P90® 3M /ESPE; G4 (teste) tratamento de superfície por jateamento com óxido de alumínio + Sistema adesivo P90 3M /ESPE + Filtek P90® 3M /ESPE. Após o tratamento (baseline) e em 12 meses, dois examinadores treinados avaliaram as restaurações utilizando o método da World Dental Federation. A normalidade da distribuição dos dados foi verificada para cada variável resposta, utilizando o teste de Kolmogorov-Smirnov (p≤0,05). O teste de Kruskal-Wallis buscou diferenças significativas entre os grupos. Resultados: a amostra resultou em 123 restaurações confeccionadas e avaliadas em 12 meses, período em que cerca de 98% das restaurações foram classificadas como “clinicamente muito boas”, não tendo sido encontradas diferenças estatisticamente significativas quando as diferentes estratégias testadas. Conclusões: o uso adicional de ácido fosfórico ou do jato de óxido de alumínio em combinação com sistemas adesivos auto-condicionantes não influenciou as taxas de sensibilidade pós-operatória
Abstract: Aim: this study evaluated postoperative sensitivity in patients with silorane based composite restorations under different adhesion protocols. Methodology: this was a clinical trial with a controlled, randomized, longitudinal design. The study included 26 patients recruited from those who appeared routinely at the university dental clinics. Each restoration chosen as a sample unit was made following one of the following three adhesion protocols: G1 (control 1) - Surface treatment with self-etching adhesive system Adper SE Plus 3M/ESPE Filtek P60® + 3M/ESPE; G2 (control 2) – Surface treatment with self etching adhesive system P90 3M/ESPE + Filtek P90® + 3M / ESPE; G3 (test) - surface treatment with 37% phosphoric acid + P90 adhesive system 3M/ESPE Filtek P90® + 3M/ESPE; G4 (test) - Surface treatment by blasting with aluminum oxide + P90 adhesive system 3M/ESPE + Filtek P90® + 3M / ESPE. Two trained examiners evaluated the restorations for postoperative sensitivity right after the treatment (baseline) and after 12 months. The restorations were assigned the classifications for the clinical evaluation method proposed by the FDI World Dental Federation. The normal distribution of the data was verified for each dependent variable, using the Kolmogorov-Smirnov test (p ≤ 0.05). The Kruskal-Wallis test was used to identify significant differences in postoperative sensitivity among the treatment groups at baseline and after one year. Results: a total of 123 restorations were made and evaluated in 12 months. Among these, 98% were classified as “clinically very good,” and no significant statistical differences were found among all the tested adhesion strategies. Conclusion: the additional use of phosphoric acid or aluminum oxide blasting in combination with adhesive systems did not influence postoperative hypersensitivity rates
Subject: Resinas compostas
Resinas de silorano
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: FAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/46803
Issue Date: 2016
metadata.dc.url.externa: https://www.periodicos.unimontes.br/index.php/unicientifica/article/view/1768
metadata.dc.relation.ispartof: Unimontes Científica
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.