Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/47195
Tipo: Artigo de Periódico
Título: Meld pre-hepatic transplantation and RMS of the diaphragmatic domes interference in time for postoperative extubation
Autor(es): Rayssa Pistilli Duarte
Aurea Maria Oliveira da Silva
Rodrigo Marques Tonella
Lígia Dos Santos Roceto Ratti
Ilka de Fatima Santana Ferreira Boin
Resumo: Introduction: The liver transplantation procedure, in addition to its prolonged surgical time, also predisposes to complications such as changes in respiratory mechanics, lung volumes and gas exchange. Objective. this study aims to verify if clinical factors related to the receptor, namely immediate pre-transplant MELD score (Model for End-Stage Liver Disease), surgical time and Root Square Metric (RMS) of the diaphragmatic domes, interfere in the time for extubation after liver transplantation. Method: A prospective study, with a sample collected for convenience, which gathered age (years), gender (male/female), MELD score immediately prior to transplantation (without the addition of special situation scores), surgical time and time for extubation in minutes. The latter were recorded in the evolution of the physiotherapy team and the surface electromyography EMG/Brazil were performed within 30 minutes after elective extubation, by a single researcher, with supplemental oxygen support, maintaining a Sp02 ≥95% and following protocol of positioning and acquisition of electromyographic signals, based on the study of Oliveira et al. (2012). Results: For the 21 patients studied, the RMS of the left dome showed a moderate intensity correlation (−0.56) with the time of extubation, and linear multiple regression model the left dome (P=0.013) and preoperative MELD score (P=0.048) showed significant interference with extubation time. Conclusion: The preoperative MELD score and the RMS values of the left dome interfere significantly in the time for patient extubation after liver transplantation, showing the effect of previously installed muscle weakness and preoperative MELD score on postoperative outcome.
Assunto: Transplante de fígado
Respiração artificial
Desmame do respirador
Mecânica respiratória
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: EEF - DEPARTAMENTO DE FISIOTERAPIA
Tipo de Acesso: Acesso Restrito
Identificador DOI: https://doi.org/10.1016/j.hpb.2018.06.2389
URI: http://hdl.handle.net/1843/47195
Data do documento: Set-2018
metadata.dc.url.externa: https://www.sciencedirect.com/science/article/pii/S1365182X18337699?via%3Dihub
metadata.dc.relation.ispartof: HPB