Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/48325
Tipo: Artigo de Periódico
Título: Validation of the modified shuttle test to predict peak oxygen uptake in youth asthma patients under regular treatment
Autor(es): Fernanda de Córdoba Lanza
Mariana Mazzuca Reimberg
Raphael Mendes Ritti Dias
Rebeca Souza Scalco
Gustavo Falbo Wandalsen
Dirceu Solé
Marco Van Brussel
Erik Hulzebos
Simone Dal Corso
Tim Takken
Resumen: Background: Oxygen uptake (VO2) evaluations by cardiopulmonary exercise test is expensive and time-consuming. Estimating VO2 based on a field test would be an alternative. Objective: To develop and validate an equation to predict VO2peak based on the modified shuttle test (MST). Methods: Cross sectional study, with 97 children and adolescents with asthma. Participants were divided in two groups: the equation group (EG), to construct the equation model of VO2peak, and the cross-validation group (VG). Each subject performed the MST twice using a portable gas analyzer. The peak VO2peak during MST was used in the equation model. The patients’ height, weight, gender, and distance walked (DW) during MST were tested as independent variables. Results: The final model [-0.457 + (gender × 0.139) + (weight × 0.025) + (DW × 0.002)] explained 87% of VO2peak variation. The VO2peak predicted was similar to VO2peak measured by gas analyzer (1.9 ± 0.5 L/min and 2.0 ± 0.5 L/min, respectively) (p = 0.67), and presented significant ICC 0.91 (IC95% 0.77 to 0.96); p < 0.001. The Bland–Altman analysis showed low bias (-0.15 L/min) and limits of agreement (-0.65 to 0.35 L/min). There was no difference in DW between EG (760 ± 209 m) and VG (731 ± 180 m), p = 0.51. Conclusion: The developed equation adequately predicts VO2peak in pediatric patients with asthma.
Asunto: Capacidade motora
Asma
Consumo de oxigênio
Predição
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Departamento: EEF - DEPARTAMENTO DE FISIOTERAPIA
Tipo de acceso: Acesso Aberto
Identificador DOI: https://doi.org/10.3389/fphys.2018.00919
URI: http://hdl.handle.net/1843/48325
Fecha del documento: jul-2018
metadata.dc.url.externa: https://www.frontiersin.org/articles/10.3389/fphys.2018.00919/full
metadata.dc.relation.ispartof: Frontiers in Physiology
Aparece en las colecciones:Artigo de Periódico

archivos asociados a este elemento:
archivo Descripción TamañoFormato 
Validation of the modified shuttle test to predict peak oxygen uptake.pdf591.18 kBAdobe PDFVisualizar/Abrir


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.