Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/48977
Full metadata record
DC FieldValueLanguage
dc.creatorFabiana Barroso Rocha Moreirapt_BR
dc.creatorMarcelo Bicalho de Fucciopt_BR
dc.creatorGiane Amorim Ribeiro-Samorapt_BR
dc.creatorMarcelo Vellosopt_BR
dc.date.accessioned2023-01-18T13:47:29Z-
dc.date.available2023-01-18T13:47:29Z-
dc.date.issued2018-05-
dc.citation.volume38pt_BR
dc.citation.issue3pt_BR
dc.citation.spage193pt_BR
dc.citation.epage197pt_BR
dc.identifier.doihttps://doi.org/10.1097/HCR.0000000000000302pt_BR
dc.identifier.issn1932-751xpt_BR
dc.identifier.urihttp://hdl.handle.net/1843/48977-
dc.description.resumoPurpose: Chronic obstructive pulmonary disease reduces functional capacity, which is strongly correlated with the morbidity and mortality of patients. The BODE index considers the multifactorial nature of the disease, including the functional capacity measured by the 6-min walk test (6MWT), and this index predicts the mortality in patients with chronic obstructive pulmonary disease. Our aim was to assess whether association exists between the original BODE index and the modified BODE index by replacing the 6MWT with the scores from the Pulmonary Functional Status and Dyspnea Questionnaire—Modified version (PFSDQ-M), Human Activity Profile (HAP) questionnaire, and the results of the Glittre ADL Test (TGlittre). Methods: Twenty-eight subjects diagnosed with chronic obstructive pulmonary disease underwent the 6MWT and TGlittre and responded to the PFSDQ-M and HAP questionnaires. Four BODE index scores were obtained: 1 calculated by using the original method (ie, using the 6MWT) and 3 others calculated by using the results obtained from the TGlittre, PFSDQ-M, and HAP (the modified BODE index scores). Results: High levels of association were observed between the original BODE index and the BODE TGlittre (R2 = 0.824, P ≤ .0001), BODE PFSDQ-M (R2 = 0.803, P ≤ .0001), and BODE HAP (R2 = 0.500, P ≤ .0001). Conclusion: The BODE TGlittre, and BODE PFSDQ-M may be used as alternatives to the 6MWT when physical space is not available to perform the 6MWT or when the condition of a patient does not allow performance of the 6MWT.pt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEEF - DEPARTAMENTO DE FISIOTERAPIApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofJournal of Cardiopulmonary Rehabilitation and Preventionpt_BR
dc.rightsAcesso Restritopt_BR
dc.subjectAttitudes towards healthpt_BR
dc.subjectCOPDpt_BR
dc.subjectExercisept_BR
dc.subjectPrognosispt_BR
dc.subjectQuality of lifept_BR
dc.subject.otherAtitudes em relação à saúdept_BR
dc.subject.otherDoença pulmonar obstrutiva crônicapt_BR
dc.subject.otherExercícios físicospt_BR
dc.subject.otherPrognósticopt_BR
dc.subject.otherQualidade de vidapt_BR
dc.titleReplacement of the 6-min walk test with glittre ADL test and scores from the PFSDQ-M and HAP questionnaires in the BODE indexpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://journals.lww.com/jcrjournal/Abstract/2018/05000/Replacement_of_the_6_Min_Walk_Test_With_Glittre.9.aspxpt_BR
dc.identifier.orcidhttp://orcid.org/0000-0001-5102-369Xpt_BR
dc.identifier.orcidhttp://orcid.org/0000-0002-2352-8954pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.