Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/48992
Type: Artigo de Periódico
Title: Calibração de equipamento de TDR em condições de laboratório e campo para dois tipos de tubos de acesso
Other Titles: TDR equipment calibration in laboratory and field conditions for two types of access pipes
Authors: Clinimar Oliveira Amaral
Mário Sérgio Paiva Araújo
Elias Fernandes Sousa
Flávio Gonçalves Oliveira
Cláudio Roberto Marciano
Abstract: A Reflectometria no Domínio do Tempo (TDR) se destaca entre as técnicas utilizadas para a determinação do conteúdo de água no solo devido a características como: alta precisão, manutenção da estrutura física do solo, facilidade de manuseio e portabilidade. Todavia, sua aplicação tem sido limitada à pesquisa devido ao alto custo do equipamento, tubos de acesso e a necessidade de calibração. Nesse sentido, objetivou-se com este trabalho calibrar o TDR, em condições de laboratório e em campo, com a utilização de tubos de acesso de TECANAT e de PVC. Os resultados em laboratório foram satisfatórios para todas as calibrações nos dois tipos de tubos, com a leitura do TDR sendo representativa para estimar a umidade do Cambissolo Háplico eutrófico. Os resultados em campo foram razoáveis, para calibração da constante dielétrica nos dois tubos estudados em Argissolo Vermelho-Amarelo Distrófico, isso devido a intempéries do ambiente, textura argilosa do solo e aderência do tubo ao solo. A utilização de tubos de TECANAT e PVC necessitam de calibrações para cada solo, ficando a viabilidade de seu uso dependente ainda da qualidade de sua instalação no solo.
Abstract: The time domain reflectometry (TDR) stands out amongst the techniques used for the measurement of the water content in the soil due to characteristics such as high precision, conservation of the soil’s physical structure, easiness of use and portability. However, due to the high cost of equipment and access tubes and the need to calibrate, its application has been limited to research. Thus, the aim of this work was to calibrate the TDR, in laboratory and field conditions, using TECANAT and PVC access tubes. The results in the laboratory were satisfactory for all calibrations in the two types of tubes, with the TDR reading representative for estimating the moisture of the Typic Haplustept. The field results were reasonable for calibration of the dielectric constant in the two tubes studied in Typic Kandiudult, due to environmental factors, from clayey texture of soil and adherence of the tube to the soil. The use of TECANAT and PVC tubes requires calibrations for each soil, being that the viability of its use still depends on the quality of its installation in the soil.
Subject: Solo - Umidade
Calibração
Solos vermelhos
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.13083/reveng.v27i6.8091
URI: http://hdl.handle.net/1843/48992
Issue Date: 21-Oct-2019
metadata.dc.url.externa: https://periodicos.ufv.br/reveng/article/view/8091
metadata.dc.relation.ispartof: Engenharia na Agricultura
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.