Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/50719
Full metadata record
DC FieldValueLanguage
dc.creatorDeric Meschiari Batistapt_BR
dc.creatorMelissa Faccinipt_BR
dc.creatorFabricio Pinelli Valarellipt_BR
dc.creatorRodrigo Hermont Cançadopt_BR
dc.creatorRenata Cristina Oliveirapt_BR
dc.creatorRicardo Cesar Gobbi de Oliveirapt_BR
dc.creatorKarina Maria Salvatore de Freitaspt_BR
dc.date.accessioned2023-03-07T22:55:29Z-
dc.date.available2023-03-07T22:55:29Z-
dc.date.issued2020-
dc.citation.volume25pt_BR
dc.citation.issue6pt_BR
dc.citation.spage27pt_BR
dc.citation.epage32pt_BR
dc.identifier.doihttps://doi.org/10.1590/2177-6709.25.6.027-032.oarpt_BR
dc.identifier.issn21776709pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/50719-
dc.description.abstractIntrodução: Relatos controversos sugerem uma relação entre o padrão de crescimento e a espessura do osso alveolar cortical e seu efeito no uso de mini-implantes. Objetivo: Avaliar a influência do padrão de crescimento na espessura do osso cortical alveolar e na estabilidade e taxa de sucesso dos mini-implantes.Métodos: Cinquenta e seis mini-implantes foram inseridos na região vestibular da maxila de trinta pacientes. Esses pacientes foram alocados em dois grupos, com base em seu padrão de crescimento (grupo horizon tal [GH] e grupo vertical [GV]). As espessuras corticais foram medidas por meio de tomografias computadorizadas de feixe cônico. A estabilidade dos mini-implantes, tecido mole no local de inserção, sensibilidade durante a carga e o acúmulo de placa ao redor dos mini-implantes foram avaliados uma vez por mês. As comparações intergrupos foram realizadas por testes t de Student, testes de Mann-Whitney e testes exatos de Fisher. As correlações foram avaliadas com o coeficiente de correlação de Pearson.Resultados: A espessura do osso cortical foi significativamente maior no GH na região vestibular anterior da maxila e nas regiões vestibulares pos terior e anterior da mandíbula. Houve uma correlação negativa significativa entre o ângulo do plano mandibular (FMA) e a espessura da cortical vestibular da maxila, e com a espessura das corticais vestibular e lingual da mandíbula. Nenhuma diferença significativa entre os grupos foi encontrada com relação à mobilidade do mini-implante e taxa de sucesso. Nenhum fator associado influenciou a estabilidade dos mini-implantes.Conclusões: O padrão de crescimento afeta a espessura da cortical óssea alveolar em áreas específicas da maxila e mandíbula, com pacientes horizontais apresentando maior espessura da cortical óssea. No entanto, esse fato pode não ter influência na estabilidade e na taxa de sucesso dos mini-implantes na região vestibular posterior da maxilapt_BR
dc.description.resumoIntroduction: Controversial reports suggest a relationship between growth pattern and cortical alveolar bone thickness, and its effect in the use of mini-implants. Objective: The main purpose of this study was to assess the influence of the growth pattern on the cortical alveolar bone thickness and on the stability and success rate of mini-implants. Methods: Fifty-six mini-implants were inserted in the buccal region of the maxilla of 30 patients. These patients were allocated into two groups, based on their growth pattern (horizontal group [HG] and vertical group [VG]). Cortical thickness was measured using Cone Beam Computed Tomography. Stability of mini-implants, soft tissue in the insertion site, sensitivity during loading and plaque around the mini-implants were evaluated once a month. Intergroup comparisons were performed using t tests, Mann-Whitney tests, and Fisher exact tests. Correlations were evaluated with Pearson’s corre lation coefficient. Results: The cortical bone thickness was significantly greater in the HG at the maxillary labial anterior region and at the mandibular buccal posterior and labial anterior regions. There was a significant negative correlation between Frankfort-mandibular plane angle (FMA) and the labial cortical thickness of the maxilla, and with the labial and lingual cortical bone thicknesses of the mandible. No significant intergroup difference was found for mini-implant mobility and success rate. No associated factor influenced stability of the mini-implants. Conclusions: Growth pattern affects the alveolar bone cortical thickness in specific areas of the maxilla and mandible, with horizontal patients presenting greater cortical bone thickness. However, this fact may have no influence on the stability and success rate of mini-implants in the maxillary buccal posterior regionpt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.description.sponsorshipFAPESP - Fundação de Amparo à Pesquisa do Estado de São Paulopt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentFAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORApt_BR
dc.publisher.departmentFAO - DEPARTAMENTO DE ODONTOPEDIATRIA E ORTODONTIApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofDental Press Journal of Orthodonticspt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectOrthodontic wirespt_BR
dc.subjectEstheticspt_BR
dc.subjectOrthodonticspt_BR
dc.subject.otherCortical bonept_BR
dc.subject.otherOrthodonticspt_BR
dc.subject.otherGrowthpt_BR
dc.subject.otherMandiblept_BR
dc.subject.otherMaxillapt_BR
dc.subject.otherCone beam computed tomographypt_BR
dc.titleAttractiveness of different esthetic orthodontic wirespt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.scielo.br/j/dpjo/i/2020.v25n6/pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Attractiveness of different esthetic orthodontic wires.pdf1.93 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.