Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/53157
Tipo: Artigo de Periódico
Título: Concordância interavaliadores em avaliação da córnea de pacientes críticos
Título(s) alternativo(s): Inter-rater reliability in the assessment of the cornea of critical patients
Autor(es): Diego Dias de Araújo
Andreza Werli-Alvarenga
Natália Gherardi Almeida
Priscila Marinho Aleixo Silva
Tamara Gonçalves Rezende Macieira
Tânia Couto Machado Chianca
Resumo: Objetivo: estabelecer o grau de concordância interavaliadores na avaliação da córnea de pacientes adultos, internados em unidade de terapia intensiva de um hospital público, através do teste de fluoresceína. Métodos: trata-se de um estudo transversal com abordagem descritiva, realizado com cinco avaliadores a partir do teste de concordância na avaliação da córnea de pacientes adultos internados em unidade de terapia intensiva de um hospital público de Belo Horizonte, Minas Gerais. Oitenta e cinco pacientes foram avaliados, totalizando 170 córneas. O coeficiente kappa foi utilizado para a avaliação do grau de concordância interavaliadores e para esta análise o nível de significância adotado foi o valor p < 0,05. Resultados: verificou-se concordância geral com variação do coeficiente kappa de 0,84 a 0,93 entre os avaliadores. Os índices obtidos indicam concordâncias quase perfeitas. Conclusão: a partir dos resultados, evidencia-se que os avaliadores após capacitação para avaliação corneana estão aptos a realizar o exame da córnea em pacientes adultos internados em unidade de terapia intensiva e que a concordância interavaliadores é uma importante etapa de validação a ser utilizada na calibração de profissionais para avaliações ou análises subsequentes.
Abstract: Objective: To establish the degree of inter-rater reliability in the assessment of the cornea of adult inpatients of an intensive care unit of a public hospital, using the fluorescein-eye-stain test. Methods: Cross-sectional descriptive study, conducted with five evaluators to reach inter-rater reliability in the assessment of cornea of adult inpatients of an intensive care unit of a public hospital in the city of Belo Horizonte, state of Minas Gerais. Eighty-five patients were evaluated, totaling 170 corneas. Kappa coefficient was used to measure the degree of inter-rater reliability, and the level of significance adopted for the analysis was p <0.05. Results: Inter-rater reliability among evaluators was reached with a variation of 0.84 -0.93 for the kappa coefficient. The results obtained indicate an almost perfect reliability. Conclusion: These results show that, after receiving training for corneal assessment, the evaluators are able to examine cornea of adult inpatients of anintensive care unit. Inter-rater reliability is an important validation step to use in the education of professionals to perform assessment, or for further analyses.
Assunto: Córnea
Unidades de Terapia Intensiva
Reprodutibilidade dos testes
Avaliação em enfermagem
Idioma: por
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: ENF - DEPARTAMENTO DE ENFERMAGEM BÁSICA
Tipo de Acesso: Acesso Aberto
Identificador DOI: https://doi.org/10.19175/recom.v7i0.1392
URI: http://hdl.handle.net/1843/53157
Data do documento: 2017
metadata.dc.url.externa: http://www.seer.ufsj.edu.br/index.php/recom/article/view/1392
metadata.dc.relation.ispartof: Revista de Enfermagem do Centro-Oeste Mineiro
Aparece nas coleções:Artigo de Periódico

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Concordância interavaliadores em avaliação da córnea de pacientes críticos.pdf170.68 kBAdobe PDFVisualizar/Abrir


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.