Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/53665
Full metadata record
DC FieldValueLanguage
dc.creatorWarley Ferreira Felixpt_BR
dc.creatorMaria Auxiliadora Fortini Velosopt_BR
dc.creatorMarcos Eugênio Silva Abrantespt_BR
dc.creatorRamon Vitor de Mirandapt_BR
dc.creatorVitor Araújo Rosaspt_BR
dc.date.accessioned2023-05-19T19:51:43Z-
dc.date.available2023-05-19T19:51:43Z-
dc.date.issued2021-04-30-
dc.citation.volume9pt_BR
dc.citation.issue1Apt_BR
dc.identifier.doihttps://doi.org/10.15392/bjrs.v9i1A.1398pt_BR
dc.identifier.issn2319-0612pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/53665-
dc.description.abstractCom o desenvolvimento da tomografia computadorizada, os exames de tomografia vêm substituindo outras modalidades de exames de imagem. A angiotomografia computadorizada para tromboembolismo pulmonar, por exemplo, vem substituindo a cintilografia pulmonar de ventilação/perfusão e a angiografia de vasos pulmonares. Mas a angiotomografia para tromboembolismo pulmonar é um exame complexo, onde fatores como tempo de varredura, fluxo de injeção de contraste, calibre do acesso venoso, local de punção do acesso venoso, uso do injetor de contraste, parâmetros de disparo automático, entre outros, interferem no resultado do exame na população estudada. Neste estudo, realizamos a relação de contraste (RZC), relativa à opacificação do contraste no tronco da artéria pulmonar e na aorta descendente, que pode variar de acordo com o protocolo de injeção utilizado, determinado pelo fluxo de injeção de contraste (ml/s) associado aos parâmetros de disparo automático (HU) da leitura de densidade no modo automático do equipamento. Para a injeção de contraste manual, e sua média e desvio padrão de RZC(2,66±3,56), para os protocolos fluxo (ml/s) e leitura automática (HU) as médias e desvios padrão RZC consecutivamente são: 3,5 ml/s e 90 HU(3,68±2,79);3,5 ml/s e 70 HU(1,90±0,72);4,0 ml/s e 70 HU(1,98±0,56);3,0 ml/s e 80 HU(2,15±0,89);3,5 ml/ s e 80 HU(1,50±0,36);4,0 ml/s e 80 HU(3,91±3,22);4,5 ml/s e 80 HU(4,69±4,82);5,0 ml/s e 80 HU(4,27±3,78). A técnica com maior resultado no nível médio de RZC foi a que utilizou fluxo de 4,5 ml/s e disparo automático em 80 HU.pt_BR
dc.description.resumoWith the development of computed tomography, tomography examinations have been replacing other modalities of imaging tests. Computed tomography angiography to pulmonary thromboembolism, for example, has been replacing pulmonary scintigraphy of ventilation/perfusion and angiography of pulmonary vessels. But angiotomography to the pulmonary thromboembolism is a complex examination, where factors such as scanning time, contrast injection flow, venous access caliber, venous access puncture site, use of the contrast injector, automatic trigger parameters, among others, interfere in the outcome of exam in the studied population.In this study, we performed the contrast ratio (RZC), relative the opacification of contrast in the trunk of the pulmonary artery and the descending aorta, which may vary according to the injection pro-tocol used, determined by the flow of contrast injection (ml/s) associated with the automatic trigger (HU) pa-rameters of the density reading in automatic mode of the equipment. For the injection of manual contrast, and its mean and standard deviation of RZC(2.66±3.56), for the flow (ml/s) and automatics reading (HU) protocols the means and standard deviations RZC consecutively are: 3.5 ml/s and 90 HU(3.68±2.79);3.5 ml/s and 70 HU(1.90±0.72);4.0 ml/s and 70 HU(1.98±0.56);3.0 ml/s and 80 HU(2.15±0.89);3.5 ml/s and 80 HU(1.50±0.36);4.0 ml/s and 80 HU(3.91±3.22);4.5 ml/s and 80 HU(4.69±4.82);5.0 ml/s and 80 HU(4.27±3.78).The technique with the larger result in the average level of RZC was the one that used a flow of 4.5 ml/s and automatic trigger in 80 HU.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA NUCLEARpt_BR
dc.publisher.departmentHCL - HOSPITAL DAS CLINICASpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofBrazilian Journal of Radiation Sciencespt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectComputed tomographypt_BR
dc.subjectComputed tomography angiography for TEPpt_BR
dc.subjectFluxpt_BR
dc.subjectContrast ratiopt_BR
dc.subjectDose optimizationpt_BR
dc.subject.otherAngiografia por tomografia computadorizadapt_BR
dc.subject.otherTomografia por emissão de pósitronspt_BR
dc.subject.otherEmbolia pulmonarpt_BR
dc.subject.otherAnálise de injeção de fluxopt_BR
dc.titleInfluence of contrast injection flux on the outcome of the angiotomography for the diagnosis of pulmonary embolismpt_BR
dc.title.alternativeInfluência do fluxo de injeção de contraste no resultado da angiotomografia para o diagnóstico de embolia pulmonarpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.bjrs.org.br/revista/index.php/REVISTA/article/view/1398pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-5949-6299pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-8618-8195pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-4044-7862pt_BR
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.