Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/56583
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Wilson Campos Tavares Junior | pt_BR |
dc.creator | Eduardo Paulino | pt_BR |
dc.creator | Maria Angélica Baron Magalhaes | pt_BR |
dc.creator | Ana Clara Guimarães Gabrich Fonseca | pt_BR |
dc.creator | João Bernardo Sancio Rocha Rodrigues | pt_BR |
dc.creator | Vivian Resende | pt_BR |
dc.date.accessioned | 2023-07-18T16:45:40Z | - |
dc.date.available | 2023-07-18T16:45:40Z | - |
dc.date.issued | 2019 | - |
dc.citation.volume | 27 | pt_BR |
dc.citation.issue | 1 | pt_BR |
dc.citation.spage | 12 | pt_BR |
dc.citation.epage | 15 | pt_BR |
dc.identifier.doi | https://doi.org/10.1590/1413-785220192701132230 | pt_BR |
dc.identifier.issn | 1809-4406 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/1843/56583 | - |
dc.description.abstract | Objetivos: Avaliar a captação do gadolínio (Gd) à ressonância magnética (DCRM) em modelo experimental de lesão do tendão de Aquiles. Métodos: Foram utilizados 12 coelhos machos, adultos e brancos da raça Nova Zelândia, distribuídos em dois grupos: operados (n = 8), com ressecção da porção central do tendão de Aquiles; e o grupo controle (n=4). Após quatro semanas, realizou-se ressonância magnética com técnica de avaliação dinâmica do meio de contraste, seguido de analise histológica dos tendões. Resultados: Houve diferença (p <0,001) do pico máximo de realce de contraste, na DCRM dinâmica do tendão de Aquiles entre os grupos operado e controle, sendo evidenciada maior captação de contraste no grupo operado. À histologia, os tendões operados apresentaram desorganização de sua arquitetura, fibras tendíneas de aspecto desordenado, com neoformação vascular e proliferação de fibroblastos. Conclusão: A DCRM apresentou potencial de demonstrar alterações do padrão de vascularização do tendão de Aquiles no pré e pós-operatório. A DCRM apresenta potencial para ser usada em estudos para controle de tratamento e diagnóstico da tendinose. Nível de evidência II, Estudo Experimental. | pt_BR |
dc.description.resumo | Objective: This study aimed to evaluate the dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in the experimental model of Achilles tendon injury. Methods: Twelve white male adults New Zealand rabbits were divided into two groups, a group with resection of the central portion of the Achilles tendon (n = 8) and a control group (n = 4). Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was performed 4 weeks after the surgical procedure, followed by histological analysis of the tendons. Results: The main finding of this study was the difference (p < 0.001) in peak contrast enhancement on DCE-MRI, which demonstrated that the operated group had greater contrast uptake. The operated tendons showed histological disruption of their architecture, and cluttered appearance of tendinous fibers, with vascular and fibroblast proliferations. Conclusion: DCE-MRI is a technique with a potential to demonstrate changes in the vascularity pattern of the Achilles tendon before and after operation. DCE-MRI has a potential to be used in studies of tendinosis diagnosis and surgical follow-up. Level of evidence II, Experimental Study. | pt_BR |
dc.format.mimetype | pt_BR | |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | ICB - DEPARTAMENTO DE MORFOLOGIA | pt_BR |
dc.publisher.department | MED - DEPARTAMENTO DE ANATOMIA PATOLÓGICA E MEDICINA LEGAL | pt_BR |
dc.publisher.department | MED - DEPARTAMENTO DE CIRURGIA | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Acta Ortopédica Brasileira | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Magnetic resonance imaging | pt_BR |
dc.subject | Perfusion | pt_BR |
dc.subject | Tendon | pt_BR |
dc.subject | Wound healing | pt_BR |
dc.subject.other | Imageamento por ressonância magnética | pt_BR |
dc.subject.other | Perfusão | pt_BR |
dc.subject.other | Tendões | pt_BR |
dc.subject.other | Cicatrização | pt_BR |
dc.title | Magnetic resonance imaging perfusion technique in the evaluation of achilles tendon injury in rabbits | pt_BR |
dc.title.alternative | Técnica de perfusão à RM na avaliação da lesão do tendão de aquiles em coelhos | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://www.scielo.br/j/aob/a/kDrKb6kZMPxTn6zTngFf7sk/?lang=en# | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0003-4775-9615 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0001-6157-6511 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0002-4113-7703 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0003-4278-3982 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0001-8238-5095 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0003-4400-0427 | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Magnetic resonance imaging perfusion technique in the evaluation of achilles tendon injury in rabbits.pdf | 1.21 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.