Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/56612
Tipo: Artigo de Periódico
Título: O volume de fluxo e a velocidade de pico sistólico ao ultrassom vascular com doppler intraoperatório como preditores de perviedade precoce na fístula arteriovenosa autógena para hemodiálise
Título(s) alternativo(s): Intraoperative vascular Doppler ultrasound blood flow and peak systolic velocity predict early patency in hemodialysis arteriovenous fistula
Autor(es): Guilherme Decastro-santos
Gabriella Yuka Shiomatsu
Rafaela Martins Dos Santos Oliveira
Ricardo Jayme Procópio
Túlio Pinho Navarro
Resumo: Contexto: A insuficiência renal crônica é um problema de saúde pública mundial. A hemodiálise é a principal terapia renal substitutiva. As fístulas arteriovenosas (FAV) são uma possível escolha, mas apresentam altas taxas de falência. Objetivos: Este estudo tem como objetivo avaliar a relação entre as variáveis hemodinâmicas ao ultrassom vascular com Doppler no intraoperatório e a perviedade precoce da FAV para hemodiálise. Métodos: Tratou-se de um estudo prospectivo observacional. Os pacientes consecutivos foram submetidos a FAV com ultrassonografia vascular com Doppler em intraoperatório nos dias 1, 7, 30 e 60. Eles foram divididos em grupos quanto à presença ou não de perviedade primária e secundária, e o volume de fluxo (VF) e a velocidade de pico sistólico (VPS) foram comparados. Foram realizadas curvas receiver operating characteristic (ROC), com definição de valores de VPS e VF com sensibilidade (S) e especificidade (E). Resultados: Foram analisados 47 pacientes, os quais preencheram os critérios de inclusão. Os valores de VPS e VF intraoperatório foram maiores nos pacientes com perviedade primária e secundária comparados àqueles com falência. Os seguintes valores apresentaram maiores sensibilidade e especificidade para predizer perviedade primária aos 30 dias: 106 cm/s para VPS venoso, S: 75%, E: 71,4%; e 290,5 mL/min para VF arterial, S: 80,6%, E: 85,7%. Para perviedade secundária aos 30 dias, foram observados: 106 cm/s para VPS arterial, S: 72,7%, E: 100%; e 230 mL/min para VF venoso, com S: 86,4%, E: 100%. Para a perviedade primária no 60º dia, foram observados: 106 cm/s para VPS venoso, S: 74,4%, E: 62,5%; e 290,5 mL/min para VF arterial, S: 80%, E: 75%. Conclusões: A velocidade de pico sistólico e o VF ao ultrassom vascular com Doppler intraoperatório são preditores de perviedade precoce na FAV para hemodiálise.
Abstract: Background: Chronic kidney disease is a major public health problem. Hemodialysis is the most common renal replacement therapy. Arteriovenous fistulas (AVF) are a possible access option, but early failure rates remain high. Objectives: to investigate the value of intraoperative vascular Doppler ultrasound for predicting early AVF patency. Methods: Prospective observational study. Consecutive patients undergoing AVF were assessed with vascular Doppler ultrasonography intraoperatively and on days 1, 7, 30, and 60. Patients were divided into groups according to presence or absence of primary and secondary patency. Blood flow (BF) and peak systolic velocity (PSV) were compared. ROC curves were plotted and used to define the PSV and BF values that yielded greatest sensitivity (Sens) and specificity (Spec). Results: 47 patients met the inclusion criteria and were analyzed. Higher intraoperative PSV and BF values were observed in patients who had primary and secondary patency than in patients with access failure. The values with greatest sensitivity and specificity for predicting 30-day primary patency were 106 cm/s for venous PSV (Sens: 75% and Spec: 71.4%) and 290.5 ml/min for arterial blood flow (Sens: 80.6% and Spec 85.7%). Values for 30-day secondary patency were 106 cm/s for arterial PSV (Sens: 72.7%, Spec: 100%) and 230 ml/min for venous blood flow (Sens: 86.4%, Spec100%). Values for 60-day primary patency were 106 cm/s for venous PSV (Sens: 74.4%, Spec: 62.5%) and 290.5 ml/min for arterial blood flow (Sens: 80%, Spec: 75%). Conclusions: Peak systolic velocity and blood flow measured using intraoperative vascular Doppler ultrasound can predict early patency of hemodialysis arteriovenous fistulas.
Assunto: Fístula arteriovenosa
Ultrassom
Idioma: por
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: MED - DEPARTAMENTO DE CIRURGIA
Tipo de Acesso: Acesso Aberto
Identificador DOI: https://doi.org/10.1590/1677-5449.210098
URI: http://hdl.handle.net/1843/56612
Data do documento: 2021
metadata.dc.url.externa: https://www.scielo.br/j/jvb/a/9HqbzJxhHJkcT4zmpXcVbRS/?lang=pt
metadata.dc.relation.ispartof: Jornal Vascular Brasileiro
Aparece nas coleções:Artigo de Periódico



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.