Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/57378
Full metadata record
DC FieldValueLanguage
dc.creatorBernardo Maranhão Dantaspt_BR
dc.creatorF. F. Limapt_BR
dc.creatorA. L. Dantaspt_BR
dc.creatorE. A. Lucenapt_BR
dc.creatorRodrigo Modesto Gadelha Gontijopt_BR
dc.creatorC. B. Carvalhopt_BR
dc.creatorC. Hazinpt_BR
dc.date.accessioned2023-08-02T19:27:56Z-
dc.date.available2023-08-02T19:27:56Z-
dc.date.issued2016-
dc.citation.volume113pt_BR
dc.citation.spage1pt_BR
dc.citation.epage4pt_BR
dc.identifier.doihttps://doi.org/10.1016/j.apradiso.2016.04.007pt_BR
dc.identifier.issn09698043pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/57378-
dc.description.resumoIntakes of radionuclides can be estimated through in vivo measurements, and the uncertainties asso ciated to the measured activities should be clearly stated in monitoring program reports. This study aims to evaluate the uncertainties of in vivo monitoring of iodine 131 in the thyroid. The reference values for high-energy photons are based on the IDEAS Guide. Measurements were performed at the In VivoMonitoring Laboratory of the Institute of Radiation Protection and Dosimetry (IRD) and at the Internal Dosimetry Laboratory of the Regional Center of Nuclear Sciences (CRCN-NE). In both institutions, the experiment was performed using a NaI(Tl) 3′′3″ scintillation detector and a neck-thyroid phantom.Scattering factors were calculated and compared in different counting geometries. The results show that the technique produces reproducibility equivalent to the values suggested in the IDEAS Guide and measurement uncertainties is comparable to international quality standards for this type of in vivo monitoring.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentMED - DEPARTAMENTO DE ANATOMIA E IMAGEMpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofApplied Radiation and Isotopes-
dc.rightsAcesso Restritopt_BR
dc.subjectMeasurement uncertaintypt_BR
dc.subjectIn vivo measurementpt_BR
dc.subjectIodine-131pt_BR
dc.subjectThyroidpt_BR
dc.subject.otherGlândula Tireoidept_BR
dc.subject.otherCompostos de Iodopt_BR
dc.titleDetermination of uncertainties associated to the in vivo measurement of iodine-131 in the thyroidpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.sciencedirect.com/science/article/pii/S0969804316301300?via%3Dihubpt_BR
dc.identifier.orcid0000-0001-6479-3087pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
There are no files associated with this item.