Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/57505
Type: Artigo de Periódico
Title: Digital panoramic radiography and cone-beam computed tomography as ancillary tools to detect low bone mineral density in postmenopausal women
Authors: Camila de Nazaré Alves de Oliveira Kato
Núbia Priscilla Kleperon Tavares
Sâmila Gonçalves Barra
Tania Mara Pimenta Amaral
Lucas Guimarães de Abreu
Cláudia Borges Brasileiro
Ricardo Mesquita
Abstract: Objectives: To evaluate the usefulness of the mandibular cortical index (MCI) obtained by digital panoramic radiography (DPR) and by panoramic reconstruction (PR) of cone-beam CT (CBCT) with three different slice thicknesses for the screening of low bone mineral density (BMD) in post-menopausal women. Methods: Two trained oral and maxillofacial radiologists assessed the MCI based on the morphology of the mandibular bone cortex (classified as C1, C2 or C3). The DPR and PR of CBCT with slice thicknesses of 5, 15 or 25 mm were compared to the BMD obtained by dual-energy X-ray absorptiometry (DXA) in post-menopausal women. Measures related to accuracy were calculated with MedCalc software. The confidence interval was set at 95%. Results: 54 women (mean age 58.70 ± 7.35 years) participated in the study. The sensitivity and specificity values obtained for DPR were 52.6% and 56.2%, respectively, and values for PR of CBCT with 5, 15, and 25 mm slice thicknesses were 63.1% and 43.7%, 50.0% and 50.0%, and 52.6% and 62.5%, respectively. For the tools evaluated, the positive likelihood ratio ranged from 1.00 to 1.40 and negative likelihood ratio from 0.76 to 1.00. The positive predictive value (PPV) ranged from 70.4 to 76.9% and the negative predictive value (NPV) from 29.6 to 35.7%. Among the examinations, the highest value for area under the curve (AUC) was obtained for CBCT with 25 mm slice thickness (57.6%). Conclusions: The MCI calculated by DPR and CBCT differed with regard to accuracy. Within the limitations of this study, the PR of CBCT with 25 mm slice thicknesses seems to be the most accurate among the examinations evaluated. Should the dentist be attentive, DPR and CBCT may be useful tools for the screening of low BMD in post-menopausal women, facilitating their timely referral for further assessment.
Subject: Radiography, panoramic
Cone-beam computed tomography
Bone density
Mandible
Postmenopause
language: eng
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: FAO - DEPARTAMENTO DE CLÍNICA
FAO - DEPARTAMENTO DE ODONTOPEDIATRIA E ORTODONTIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1259/dmfr.20180254
URI: http://hdl.handle.net/1843/57505
Issue Date: 1-Nov-2018
metadata.dc.url.externa: https://www.birpublications.org/doi/10.1259/dmfr.20180254?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
metadata.dc.relation.ispartof: Dentomaxillofacial Radiology
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.