Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/57667
Type: Artigo de Periódico
Title: Intrarater and interrater agreement and reliability of vestibular evoked myogenic potential triggered by galvanic vestibular stimulation (galvanic-VEMP) for HTLV-1 associated myelopathy testing
Authors: Júlia Fonseca de Morais Caporali
Ludimila Labanca
Kyonis Rodrigues Florentino
Bárbara Oliveira Souza
Denise Utsch Gonçalves
Abstract: Background:The vestibular evoked myogenic potential triggered by galvanic vestibular stimulation (galvanic-VEMP) has been used to assess the function of the vestibulospinal motor tract and is a candidate biomarker to predict and monitor the human T-cell lymphotropic virus type 1(HTLV-1) associated myelopathy (HAM). This study determined the agreement and reliability of this exam.Methods: Galvanic-VEMP was performed in 96 participants, of which 24 patients presented HAM, 27 HTLV-1-asymptomatic carriers, and 45 HTLV-1-negative asymptomatic controls. Galvanic vestibular stimulation was achieved by passing a binaural and bipolar current at a 2 milliam peres (mA) intensity for 400 milliseconds (ms) between the mastoid processes. Galvanic VEMP electromyographic wave responses of short latency (SL) and medium latency (ML) were recorded from the gastrocnemius muscle. Intrarater (test-retest) and interrater (two independent examiners) agreement and reliability were assessed by standard error of measurement (SEM), coefficient of repeatability (CR), intraclass correlation coefficient (ICC), and Kappa coefficient. Results:In the total sample (n = 96), SL and ML medians were 56 ms (IQR 52–66) and 120 ms (IQR 107–130), respectively. The intrarater repeatability measures for SL and ML were, respectively: SEM of 6 and 8 ms; CR of 16 and 22 ms; ICC of 0.80 (p<0.001) and 0.91 (p<0.001); and a Kappa coefficient of 0.53 (p<0.001) and 0.82 (p<0.001). The interrater reproducibility measures for SL and ML were, respectively: SEM of 3 and 10 ms; CR of 8 and 27 ms; ICC of 0.95 (p<0.001) and 0.86 (p<0.001); and a Kappa coefficient of 0.77 (p<0.001) and 0.88 (p<0.001). Conclusion Galvanic-VEMP is a reliable and reproducible method to define the integrity of the vestibulospinal tract. Longitudinal studies will clarify its validity in the clinical context, aimed at achieving an early diagnosis and the monitoring of HAM.
Subject: Infecções por HTLV-I
language: eng
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: MED - DEPARTAMENTO DE CLÍNICA MÉDICA
MED - DEPARTAMENTO DE OFTALMOLOGIA E OTORRINOLARINGOLOGIA
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1371/journal.pone.0204449
URI: http://hdl.handle.net/1843/57667
Issue Date: 2018
metadata.dc.url.externa: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0204449
metadata.dc.relation.ispartof: PLOS ONE
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.