Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/57959
Type: | Artigo de Periódico |
Title: | Determination of the dose rate constant through Monte Carlo simulations with voxel phantoms |
Authors: | Abner Duarte Soares Lucas Paixão Reis Alessandro Facure |
Abstract: | Purpose: The main goal of this study was to determine the dose rate constant of radionuclides used in Nuclear Medicine when they are biodistributed in humans. The secondary goal was to calculate the effective half-life for the same radionuclides in order to determine the realistic dose due to the incorporation of these nuclides for a variety of reasons.Methods: Anthropomorphic voxel phantoms, with characteristics based on ICRP-110 were consid ered and the biodistributions of radionuclides were simulated using the Monte Carlo code MCNPX.In addition, the effective half-lives for all simulated radionuclides were calculated.Results: The results for the dose rate constant, taking into account the patient body attenuation,showed no correlation between the biodistribution of the radionuclide and the energy of the radiationemitted. Body attenuation ranged between 6.7% and 94.1%. Also, the priority angle of radiation emission was determined. The values found for the body attenuation agree with the literature, corroborating the calculation of the body dose rate constant.Conclusions: The results for the body dose rate constant calculated in this work, for 30 radionu clides and 57 radiopharmaceuticals, and their effective half-lives, may be used to estimate the dose emitted by a person who has incorporated a radionuclide in the Nuclear Medicine activity range. This dose will be optimized when the body dose rate constant and the effective half-life determined in this study are used together with dose reduction factors |
Subject: | Dosagem Método de Monte Carlo |
language: | eng |
metadata.dc.publisher.country: | Brasil |
Publisher: | Universidade Federal de Minas Gerais |
Publisher Initials: | UFMG |
metadata.dc.publisher.department: | MED - DEPARTAMENTO DE ANATOMIA E IMAGEM |
Rights: | Acesso Restrito |
metadata.dc.identifier.doi: | https://doi.org/10.1002/mp.13181 |
URI: | http://hdl.handle.net/1843/57959 |
Issue Date: | 23-Dec-2018 |
metadata.dc.url.externa: | https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/mp.13181 |
metadata.dc.relation.ispartof: | Medical Physics |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.