Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/59020
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Karina Augusta Viana | pt_BR |
dc.creator | Olindo Assis Martins Filho | pt_BR |
dc.creator | Luci Maria SantAna Dusse | pt_BR |
dc.creator | Lis Ribeiro do Valle Antonelli | pt_BR |
dc.creator | Danielle Marchetti Vitelli Avelar | pt_BR |
dc.creator | Renato Sathler Avelar | pt_BR |
dc.creator | Maria das Graças Carvalho | pt_BR |
dc.date.accessioned | 2023-09-29T11:07:53Z | - |
dc.date.available | 2023-09-29T11:07:53Z | - |
dc.date.issued | 2016-06 | - |
dc.citation.volume | 52 | pt_BR |
dc.citation.issue | 3 | pt_BR |
dc.citation.spage | 142 | pt_BR |
dc.citation.epage | 148 | pt_BR |
dc.identifier.doi | https://doi.org/10.5935/1676-2444.20160025 | pt_BR |
dc.identifier.issn | 1676-2444 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/1843/59020 | - |
dc.description.abstract | Introdução: A contagem de reticulócitos por citometria de fluxo (CF) – um método de contagem automatizada – pode apresentar erros devido à presença de interferentes, contribuindo para uma ligeira elevação dos resultados. No entanto, os métodos automatizados possuem grandes vantagens em relação ao manual, tido como referência, o que justifica esforços para a melhoria de sua qualidade. Objetivo: Avaliar a interferência de plaquetas na contagem de reticulócitos por CF, utilizando laranja de tiazol (thiazole orange [TO]) (CF/TO). Materiais e métodos: O método de contagem de reticulócitos por CF/TO e um método equivalente automatizado modificado, no qual se excluíram células CD61-positivas (plaquetas) da análise (CF/TO/MOD), foram comparados com o método manual. Conclusão: Os resultados foram analisados de acordo com as recomendações do Clinical and Laboratory Standards Institute (CLSI) para avaliar a intercambialidade entre os métodos, por meio da análise de regressão linear e do teste t pareado. A exclusão de interferentes da análise dos resultados pelo método modificado demonstrou maior proximidade dos resultados com aqueles do método de referência. | pt_BR |
dc.description.resumo | Introduction: The reticulocyte count by flow cytometry (FC) – an automated counting method – can present errors due to the presence of interfering factors, contributing to a slight increase in results. However, automated methods have large advantages over the manual method, taken as reference, what justifies efforts to improve their quality. Objective: Evaluate platelet interference with the reticulocyte count by FC, using thiazole orange (TO) (FC/TO). Materials and methods: The method of reticulocyte count by FC/TO and a modified automated equivalent method, which excluded CD61-positive cells (platelets) from analysis (FC/TO/MOD), were compared to the manual method. Conclusion: Results were analyzed according to the recommendations of the Clinical and Laboratory Standards Institute (CLSI) to assess interchangeability between the methods, by linear regression analysis and paired t-test. The exclusion of interfering fragments from result analysis by the modified method produced results in closer proximity to those of the reference method. | pt_BR |
dc.format.mimetype | pt_BR | |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | FAR - DEPARTAMENTO DE ANÁLISES CLÍNICAS E TOXICOLÓGICAS | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Jornal Brasileiro de Patologia e Medicina Laboratorial | - |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Reticulocyte count | pt_BR |
dc.subject | Flow cytometry | pt_BR |
dc.subject | Blood platelets | pt_BR |
dc.subject.other | Hematologia | pt_BR |
dc.subject.other | Contagem de reticulócitos | pt_BR |
dc.subject.other | Citometria de fluxo | pt_BR |
dc.subject.other | Plaquetas | pt_BR |
dc.title | Evaluation of the interference of platelets in reticulocyte counting by flow cytometry using thiazole orange | pt_BR |
dc.title.alternative | Avaliação da interferência de plaquetas na contagem de reticulócitos por citometria de fluxo, utilizando laranja de tiazol | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://jbpml.org.br/j-bras-patol-med-lab-vol-52-issue-3-2016 | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Evaluation of the interference of platelets in reticulocyte counting by flow cytometry using thiazole orange.pdf | 336.07 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.