Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/61196
Full metadata record
DC FieldValueLanguage
dc.creatorLucas Victor Pereira de Freitaspt_BR
dc.creatorGleysson de Paula Terrapt_BR
dc.creatorSilas de Souza Santospt_BR
dc.creatorLázaro Chaves Sicupirapt_BR
dc.creatorFlaviano Oliveira Silvériopt_BR
dc.date.accessioned2023-11-21T18:36:45Z-
dc.date.available2023-11-21T18:36:45Z-
dc.date.issued2022-07-06-
dc.citation.volume14pt_BR
dc.citation.issue30pt_BR
dc.citation.spage2945pt_BR
dc.citation.epage2952pt_BR
dc.identifier.doihttps://doi.org/10.1039/D2AY01004Fpt_BR
dc.identifier.issn1759-9679pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/61196-
dc.description.resumoFluopyram is a fungicide and nematicide that belongs to the chemical group of benzamides, which act as succinate dehydrogenase inhibitors (SDHIs) on the mitochondrial respiratory chain of fungi. Despite being well known in several countries, there are few studies involving the optimization and validation of extraction methods for determining fluopyram in water samples. Therefore, this study aimed to optimize and validate liquid–liquid extraction with low-temperature purification (LLE-LTP) to determine fluopyram fungicide in water samples using high-performance liquid chromatography with diode array detection (HPLC-DAD). A two-level full factorial design was employed to optimize LLE-LTP which enabled achieving a recovery rate close to 100% and relative standard deviations (RSD) < 10.0%. The validation showed that the extraction method may be considered selective, precise, accurate, and linear in the range of 6.0 to 200 μg L−1. The LOD and LOQ were 4.0 and 6.0 μg L−1, respectively, proving the efficiency of this method for trace level determination of this fungicide in water samples. LLE-LTP coupled to HLPC-DAD analysis showed a matrix effect of less than 8% and it was applied in monitoring 20 environmental water samples, but no fluopyram residue was detected in the samples.pt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentICA - INSTITUTO DE CIÊNCIAS AGRÁRIASpt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofAnalytical Methods-
dc.rightsAcesso Restritopt_BR
dc.subject.otherFungicidaspt_BR
dc.subject.otherÁgua - Qualidadept_BR
dc.subject.otherÁgua - Teor de pesticidaspt_BR
dc.titleOptimization and validation of liquid-liquid extraction with low-temperature purification (LLE-LTP) for determining fluopyram fungicide in water samples using HPLC-DADpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://pubs.rsc.org/en/content/articlelanding/2022/ay/d2ay01004fpt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.