Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/61196
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Lucas Victor Pereira de Freitas | pt_BR |
dc.creator | Gleysson de Paula Terra | pt_BR |
dc.creator | Silas de Souza Santos | pt_BR |
dc.creator | Lázaro Chaves Sicupira | pt_BR |
dc.creator | Flaviano Oliveira Silvério | pt_BR |
dc.date.accessioned | 2023-11-21T18:36:45Z | - |
dc.date.available | 2023-11-21T18:36:45Z | - |
dc.date.issued | 2022-07-06 | - |
dc.citation.volume | 14 | pt_BR |
dc.citation.issue | 30 | pt_BR |
dc.citation.spage | 2945 | pt_BR |
dc.citation.epage | 2952 | pt_BR |
dc.identifier.doi | https://doi.org/10.1039/D2AY01004F | pt_BR |
dc.identifier.issn | 1759-9679 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/1843/61196 | - |
dc.description.resumo | Fluopyram is a fungicide and nematicide that belongs to the chemical group of benzamides, which act as succinate dehydrogenase inhibitors (SDHIs) on the mitochondrial respiratory chain of fungi. Despite being well known in several countries, there are few studies involving the optimization and validation of extraction methods for determining fluopyram in water samples. Therefore, this study aimed to optimize and validate liquid–liquid extraction with low-temperature purification (LLE-LTP) to determine fluopyram fungicide in water samples using high-performance liquid chromatography with diode array detection (HPLC-DAD). A two-level full factorial design was employed to optimize LLE-LTP which enabled achieving a recovery rate close to 100% and relative standard deviations (RSD) < 10.0%. The validation showed that the extraction method may be considered selective, precise, accurate, and linear in the range of 6.0 to 200 μg L−1. The LOD and LOQ were 4.0 and 6.0 μg L−1, respectively, proving the efficiency of this method for trace level determination of this fungicide in water samples. LLE-LTP coupled to HLPC-DAD analysis showed a matrix effect of less than 8% and it was applied in monitoring 20 environmental water samples, but no fluopyram residue was detected in the samples. | pt_BR |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | ICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Analytical Methods | - |
dc.rights | Acesso Restrito | pt_BR |
dc.subject.other | Fungicidas | pt_BR |
dc.subject.other | Água - Qualidade | pt_BR |
dc.subject.other | Água - Teor de pesticidas | pt_BR |
dc.title | Optimization and validation of liquid-liquid extraction with low-temperature purification (LLE-LTP) for determining fluopyram fungicide in water samples using HPLC-DAD | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://pubs.rsc.org/en/content/articlelanding/2022/ay/d2ay01004f | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.