Use este identificador para citar o ir al link de este elemento:
http://hdl.handle.net/1843/63176
Tipo: | Artigo de Periódico |
Título: | Performance and reference intervals of thrombin generation test: results from the brazilian longitudinal study of adult health (elsa-brasil). a cross-sectional study |
Autor(es): | Danyelle Romana Alvesrios Sandhi Maria Barreto Letícia Gonçalves Resende Ferreira Thaís Resende Batista Ana Paula Ferreira Silva Wander Valadares de Oliveira Júnior Chams Bicalho Maluf Maria Das Gracas Carvalho Roberta Carvalho Figueiredo |
Resumen: | BACKGROUND: The thrombin generation test (TGT) has shown promise for investigation of hemorrhag ic and thrombotic diseases. However, despite its potential, it still needs standardization. Moreover, few studies have established reference values for TGT parameters. In Brazil, these values have not yet been established. OBJECTIVE: To determine TGT performance and reference intervals for TGT parameters in healthy individuals. DESIGN AND SETTING: Cross-sectional study conducted among participants in the Brazilian Longitudinal Study of Adult Health (Estudo Longitudinal de Saúde do Adulto, ELSA-Brasil).METHODS: The reference sample consisted of 620 healthy individuals. The calibrated automated throm bogram (CAT) method, under low and high tissue factor (TF) conditions, was used to assess thrombin generation. Test performance was analyzed using intra and interassay coefficients of variation (CV) and reference intervals were calculated using the nonparametric method proposed by the International Fed eration of Clinical Chemistry and the Clinical and Laboratory Standards Institute. RESULTS: The intraassay CV ranged from 1.4% to 2.2% and the interassay CV, 6.8% to 14.7%. The reference intervals for TGT parameters under low and high TF conditions were, respectively: lagtime: 3.0-10.3 and 1.4-3.7 min; endogenous thrombin potential (ETP): 1134.6-2517.9 and 1413.6-2658.0 nM.min; normalized ETP: 0.6-1.3 and 0.7-1.4; peak: 103.2-397.7 and 256.4-479.0 nM; normalized peak: 0.3-1.3 and 0.7-1.2; and time-to-peak: 5.6-16.0 and 3.4-6.7 min. These parameters were categorized relative to sex. CONCLUSION: TGT performance was adequate and the proposed reference intervals were similar to those of other studies. Our findings may be useful for consolidating the TGT, through contributing to its standardization and validation. |
Asunto: | Clinical Laboratory Techniques Thrombin Reference Values |
Idioma: | eng |
País: | Brasil |
Editor: | Universidade Federal de Minas Gerais |
Sigla da Institución: | UFMG |
Departamento: | FAR - DEPARTAMENTO DE ANÁLISES CLÍNICAS E TOXICOLÓGICAS MED - DEPARTAMENTO DE MEDICINA PREVENTIVA SOCIAL MED - DEPARTAMENTO DE PROPEDÊUTICA COMPLEMENTAR |
Tipo de acceso: | Acesso Aberto |
Identificador DOI: | 10.1590/1516-3180.2021.0425.r1.07102021 |
URI: | http://hdl.handle.net/1843/63176 |
Fecha del documento: | 2022 |
metadata.dc.url.externa: | https://doi.org/10.1590/1516-3180.2021.0425.R1.07102021 |
metadata.dc.relation.ispartof: | Sao Paulo Medical Journal |
Aparece en las colecciones: | Artigo de Periódico |
archivos asociados a este elemento:
archivo | Descripción | Tamaño | Formato | |
---|---|---|---|---|
Performance and reference intervals of thrombin pdfa.pdf | 462.91 kB | Adobe PDF | Visualizar/Abrir |
Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.