Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/63445
Type: Artigo de Periódico
Title: Validação do peso autorreferido entre usuários do Programa Academia da Saúde de Belo Horizonte, Minas Gerais, 2017
Other Titles: Validation of self-reported weight among users of the Belo Horizonte Health Fitness Center Program, Minas Gerais, Brazil, 2017
Validación del peso autoinformado entre los usuarios del Programa Academia de Salud de Belo Horizonte, Minas Gerais, Brasil, 2017
Authors: Patrícia Pinheiro de Freitas
Sueli Aparecida Mingoti
Aline Cristine Souza Lopes
Abstract: Objetivo: validar o peso corporal autorreferido de usuários do Programa Academia da Saúde (PAS), Belo Horizonte, MG, Brasil, e verificar fatores associados ao erro do peso Métodos: o peso corporal autorreferido, obtido por entrevista telefônica, foi comparado ao peso mensurado; empregou-se teste t de Student, método ANOVA, coeficiente de correlação de concordância de Lin, método Bland-Altman e índice Kappa; para mulheres, o peso autorreferido foi corrigido, frente ao mensurado, por regressão múltipla. Resultados: participaram 441 usuários; homens relataram seu peso de forma válida (erro=0; p=0,15); a concordância para classificação de excesso de peso foi de 94,3% (Kappa=0,88); mulheres com >30 anos e excesso de peso apresentaram maior erro no relato (-0,8kg; erro≠0; p<0,01); após correção por regressão múltipla, a validade do peso autorreferido foi satisfatória (erro=0; p=0,99). Conclusão: para homens, medidas autorreferidas de peso podem ser utilizadas em pesquisas e na vigilância à saúde; para mulheres, fez-se necessária a correção.
Abstract: Objective: to validate self-reported body weight of Health Fitness Center Program (HFCP) users in Belo Horizonte, MG, Brazil, and to identify factors associated with weight error. Methods: self-reported body weight, obtained by telephone interview, was compared to measured weight; we used Student’s t-test, ANOVA, Lin’s concordance correlation coefficient, the Bland-Altman method and Kappa coefficient; women’s self-reported weight was corrected according to measured weight using multiple regression. Results: 441 users participated; weight self-reported by men was valid (error=0; p=0.15); overweight classification concordance was 94.3% (Kappa=0.88); errors were greater in the case of self-reported weight by women over 30 years old and overweight women (-0.8kg; error≠0; p<0.01); after correction using multiple regression, self-reported weight validity was satisfactory (error=0; p=0.99). Conclusion: self-reported weight of men can be used for research and health surveillance, but for women correction is required.
Subject: Peso corporal
Estudo de validação
Planos e programas de saúde
Autorrelato
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: ENF - DEPARTAMENTO DE ENFERMAGEM APLICADA
ENF - DEPARTAMENTO DE NUTRIÇÃO
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.5123/S1679-49742020000300010
URI: http://hdl.handle.net/1843/63445
Issue Date: Jun-2020
metadata.dc.url.externa: https://www.scielo.br/j/ress/a/tKnDhDZ8Dk9JQS4t9PSjqbd/?format=html&lang=pt
metadata.dc.relation.ispartof: Epidemiologia e Serviços de Saúde
Appears in Collections:Artigo de Periódico



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.