Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/65384
Type: | Artigo de Periódico |
Title: | Identificação de fatores que alteram a confiabilidade da temperatura axilar em relação à temperatura de cateter de artéria pulmonar |
Other Titles: | Identification of factors that alter axillary temperature reliability in relation to pulmonary artery catheter temperature Identificación de factores que alteran la confiabilidad de la temperatura axilar em relación a la temperatura del catéter de la arteria pulmonar |
Authors: | Rafael Lima Rodrigues Carvalho Mariana Avendanha Victoriano Camila Cláudia Campos Selme Silqueira de Matos Vania Regina Goveia Flavia Falci Ercole |
Abstract: | Objetivos: identificar fatores que alteram a confiabilidade da temperatura axilar em relação à temperatura de cateter artéria pulmonar. Métodos: estudo de medidas repetidas utilizando 67 aferições de temperatura axilar coletadas de 24 pacientes internados em centros de terapia intensiva de dois hospitais da região metropolitana de Belo Horizonte entre 2017 e 2018. Realizada análise descritiva e regressão linear dos dados. Resultados: foram encontradas acurácia de 0,48 e precisão de 0,47 referentes à temperatura axilar aferida com termômetro digital comparada com a temperatura de cateter de artéria pulmonar. Os fatores que alteram a confiabilidade da temperatura axilar foram o índice de massa corporal e a dose de dobutamina. Conclusão: os fatores encontrados foram inéditos em relação à alteração da confiabilidade da temperatura axilar e poderão auxiliar enfermeiros na tomada de decisão ao escolherem um método mais preciso para estimativa da temperatura real do corpo. Ainda é necessária a realização de estudos com amostragem maior para avaliação dos fatores intervenientes da confiabilidade de técnicas de temperatura não invasivas, como a temperatura axilar. |
Abstract: | Objectives: to identify factors that alter the reliability of axillary temperature in relation to pulmonary artery catheter temperature. Methods: studying repeated measures using 67 axillary temperature measurements collected from 24 patients admitted to intensive care centers of two hospitals in the metropolitan region of Belo Horizonte between 2017 and 2018. Descriptive analysis and linear regression of the data were performed. Results: accuracy of 0.48 and precision of 0.47 were found for axillary temperature measured with a digital thermometer compared with pulmonary artery catheter temperature. Factors that change the reliability of axillary temperature were body mass index and dobutamine dose. Conclusion: the found factors were unprecedented in relation to the change in axillary temperature reliability and may help nurses in their decision making by choosing a more accurate method to estimate the actual body temperature. Studies with larger sampling are still necessary to evaluate the intervening factors of the reliability of noninvasive temperature techniques, such as axillary temperature. |
Subject: | Axila Termômetros Artéria Pulmonar Temperatura Corporal |
language: | por |
metadata.dc.publisher.country: | Brasil |
Publisher: | Universidade Federal de Minas Gerais |
Publisher Initials: | UFMG |
metadata.dc.publisher.department: | ENF - DEPARTAMENTO DE ENFERMAGEM BÁSICA ENFERMAGEM - ESCOLA DE ENFERMAGEM |
Rights: | Acesso Aberto |
metadata.dc.identifier.doi: | https://doi.org/10.5935/1415-2762.20190115 |
URI: | http://hdl.handle.net/1843/65384 |
Issue Date: | 17-Feb-2020 |
metadata.dc.url.externa: | https://periodicos.ufmg.br/index.php/reme/article/view/49720 |
metadata.dc.relation.ispartof: | Revista Mineira de Enfermagem |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
IDENTIFICAÇÃO DE FATORES QUE ALTERAM A CONFIABILIDADE DA TEMPERATURA AXILAR EM RELAÇÃO À TEMPERATURA DE CATETER DE ARTÉRIA PULMONAR.pdf | 190.83 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.