Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/65384
Tipo: Artigo de Periódico
Título: Identificação de fatores que alteram a confiabilidade da temperatura axilar em relação à temperatura de cateter de artéria pulmonar
Título(s) alternativo(s): Identification of factors that alter axillary temperature reliability in relation to pulmonary artery catheter temperature
Identificación de factores que alteran la confiabilidad de la temperatura axilar em relación a la temperatura del catéter de la arteria pulmonar
Autor(es): Rafael Lima Rodrigues Carvalho
Mariana Avendanha Victoriano
Camila Cláudia Campos
Selme Silqueira de Matos
Vania Regina Goveia
Flavia Falci Ercole
Resumen: Objetivos: identificar fatores que alteram a confiabilidade da temperatura axilar em relação à temperatura de cateter artéria pulmonar. Métodos: estudo de medidas repetidas utilizando 67 aferições de temperatura axilar coletadas de 24 pacientes internados em centros de terapia intensiva de dois hospitais da região metropolitana de Belo Horizonte entre 2017 e 2018. Realizada análise descritiva e regressão linear dos dados. Resultados: foram encontradas acurácia de 0,48 e precisão de 0,47 referentes à temperatura axilar aferida com termômetro digital comparada com a temperatura de cateter de artéria pulmonar. Os fatores que alteram a confiabilidade da temperatura axilar foram o índice de massa corporal e a dose de dobutamina. Conclusão: os fatores encontrados foram inéditos em relação à alteração da confiabilidade da temperatura axilar e poderão auxiliar enfermeiros na tomada de decisão ao escolherem um método mais preciso para estimativa da temperatura real do corpo. Ainda é necessária a realização de estudos com amostragem maior para avaliação dos fatores intervenientes da confiabilidade de técnicas de temperatura não invasivas, como a temperatura axilar.
Abstract: Objectives: to identify factors that alter the reliability of axillary temperature in relation to pulmonary artery catheter temperature. Methods: studying repeated measures using 67 axillary temperature measurements collected from 24 patients admitted to intensive care centers of two hospitals in the metropolitan region of Belo Horizonte between 2017 and 2018. Descriptive analysis and linear regression of the data were performed. Results: accuracy of 0.48 and precision of 0.47 were found for axillary temperature measured with a digital thermometer compared with pulmonary artery catheter temperature. Factors that change the reliability of axillary temperature were body mass index and dobutamine dose. Conclusion: the found factors were unprecedented in relation to the change in axillary temperature reliability and may help nurses in their decision making by choosing a more accurate method to estimate the actual body temperature. Studies with larger sampling are still necessary to evaluate the intervening factors of the reliability of noninvasive temperature techniques, such as axillary temperature.
Asunto: Axila
Termômetros
Artéria Pulmonar
Temperatura Corporal
Idioma: por
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Departamento: ENF - DEPARTAMENTO DE ENFERMAGEM BÁSICA
ENFERMAGEM - ESCOLA DE ENFERMAGEM
Tipo de acceso: Acesso Aberto
Identificador DOI: https://doi.org/10.5935/1415-2762.20190115
URI: http://hdl.handle.net/1843/65384
Fecha del documento: 17-feb-2020
metadata.dc.url.externa: https://periodicos.ufmg.br/index.php/reme/article/view/49720
metadata.dc.relation.ispartof: Revista Mineira de Enfermagem
Aparece en las colecciones:Artigo de Periódico



Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.