Please use this identifier to cite or link to this item:
http://hdl.handle.net/1843/67347
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.creator | Emerson A.alvarenga | pt_BR |
dc.creator | Gustavo Henrique Ferreira Abreu Moreira | pt_BR |
dc.creator | Elias Facury Filho | pt_BR |
dc.creator | Fabiola de Oliveira Paes Leme | pt_BR |
dc.creator | Tiago Facury Moreira | pt_BR |
dc.creator | Antônio Último de Carvalho | pt_BR |
dc.date.accessioned | 2024-04-17T20:31:18Z | - |
dc.date.available | 2024-04-17T20:31:18Z | - |
dc.date.issued | 2019 | - |
dc.citation.volume | 71 | pt_BR |
dc.citation.issue | 4 | pt_BR |
dc.citation.spage | 1425 | pt_BR |
dc.citation.epage | 1427 | pt_BR |
dc.identifier.doi | https://doi.org/10.1590/1678-4162-10164 | pt_BR |
dc.identifier.issn | 1678-4162 | pt_BR |
dc.identifier.uri | http://hdl.handle.net/1843/67347 | - |
dc.description.abstract | Cetose subclínica é uma grande preocupação em rebanhos leiteiros, e seu diagnóstico e prevenção podem ter um grande impacto na saúde animal. Este estudo comparou quatro locais diferentes para a coleta de amostras de sangue (jugular, veias mamárias e coccígeas e ponta da cauda) para medição de β-hidroxibutirato (BHBA), usando-se um medidor portátil automático. Foram utilizadas seis vacas Holandesas, e a coleta de sangue foi feita no segundo, quinto, 10º, 15º e 21º dias pós-parto. Os resultados do medidor portátil foram semelhantes aos resultados do laboratório e apresentaram uma correlação forte de 0,83. As concentrações séricas de BHBA nas amostras de sangue coletadas na ponta da cauda, na jugular e na coccígea foram semelhantes. No entanto, o sangue retirado da veia mamária tinha uma concentração mais baixa. Portanto, as amostras de sangue para aferição de BHBA podem ser recolhidas nas veias jugular e coccígeas e na ponta da cauda, sendo as duas últimas as opções mais fáceis para monitorar o BHBA em rebanho leiteiro. | pt_BR |
dc.description.resumo | Subclinical ketosis is a major concern in dairy herds, and its diagnosis and prevention can have a major impact on animal health. This study compared four different sites for collecting blood samples (jugular, mammary and coccygeal veins, and tip of the tail) for measuring β-hydroxybutyrate (BHBA), using an automatic portable meter. Six Holstein cows were used, and blood collection was carried out on the second, fifth, 10th, 15th and 21st days postpartum. The portable meter results were similar to the laboratory results and showed a strong correlation of 0.83. Serum BHBA concentrations in blood samples collected from the tip of the tail, jugular and coccygeal were similar. However, blood taken from the mammary vein had a lower concentration. Therefore, blood samples for measuring BHBA can be collected from the jugular and coccygeal veins and the tip of the tail, the latter two being the easiest options for monitoring BHBA in a dairy herd. | pt_BR |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | VET - DEPARTAMENTO DE CLÍNICA E CIRURGIA | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Arquivo Brasileiro de Medicina Veterinária e Zootecnia | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Dairy cows | pt_BR |
dc.subject | Ketosis | pt_BR |
dc.subject | Transition period | pt_BR |
dc.subject | Diagnosis | pt_BR |
dc.subject.other | Vaca leiteira | pt_BR |
dc.subject.other | Cetose | pt_BR |
dc.subject.other | Coleta de amostras sanguíneas | pt_BR |
dc.subject.other | Diagnóstico | pt_BR |
dc.title | Evaluation of different sites for blood collection for β-hydroxybutyrate assessment in dairy cows using hand-held meter | pt_BR |
dc.title.alternative | Avaliação de diferentes locais de coleta de sangue para avaliação de β-hidroxibutirato em vacas de leite usando aparelho portátil automático | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://www.scielo.br/j/abmvz/a/rjzprgyGCyPmRyXLJtfhKvj/?lang=en# | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0002-4470-6246 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0001-8456-3297 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0003-0836-2105 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0002-4013-0147 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0002-0808-1955 | pt_BR |
dc.identifier.orcid | http://orcid.org/0000-0002-8041-796X | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Evaluation of different sites for blood collection for β-hydroxybutyrate assessment in dairy cows using hand-held meter.pdf | 119.33 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.