Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/68227
Tipo: Artigo de Periódico
Título: Determination of polycyclic aromatic hydrocarbons in eggs exposed to fire using a simple and efficient method
Autor(es): Vitor Vaz de Melo Antipoff
Rosimeire Resende dos Santos
Daniella Vasconcellos Augusti
Zenilda de Lourdes Cardeal
Helvécio Costa Menezes
Resumen: The illicit burn practices on farms promote food contamination that is harmful and must be controlled by improved analytical methods. Polycyclic aromatic hydrocarbons (PAHs), which have high toxic and carcinogenic potential, can contaminate foods, mainly through fire exposure. Considering the toxicity of PAHs, development of sensitive, simple, and solvent-free methods to analyze PAHs in foods is necessary. This work presents the development of a new method to analyze PAHs in eggs using cold fiber-solid-phase microextraction (CF-SPME) and gas chromatography coupled to mass spectrometry (GC-MS). Parameters of temperature extraction, ultrasonic agitation time, sample mass, and modifiers were evaluated to obtain the best CF-SPME conditions. The new method uses a minimal amount of solvent and showed good linearity in the range of 0.0005 to 5.60μg/g. Detection limits were from 0.0002 to 0.046μg/g, and quantification limits were from 0.0005 to 0.152μg/g. The method was applied to PAHs analysis of chicken egg samples from a farm near a site of an uncontrolled tire fire. The concentrations of PAHs in this study ranged from 0.926 to 1.668μg/g. All PAHs were detected in the samples. The total toxicity was estimated by benzo(a)pyrene equivalent (BaPeq) and did not decrease significantly in the period (6 weeks) of sample collection.
Asunto: Hidrocarbonetos policiclicos aromaticos
Espectrometria de massa
Cromatografia a gás
Ovos
Poluição
Alimentos - Contaminação
Idioma: eng
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Departamento: ICX - DEPARTAMENTO DE QUÍMICA
Tipo de acceso: Acesso Restrito
Identificador DOI: https://doi.org/10.1007/s12161-021-01971-z
URI: http://hdl.handle.net/1843/68227
Fecha del documento: 2021
metadata.dc.url.externa: https://link.springer.com/article/10.1007/s12161-021-01971-z
metadata.dc.relation.ispartof: Food Analytical Methods
Aparece en las colecciones:Artigo de Periódico

archivos asociados a este elemento:
no existem archivos asociados a este elemento.


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.