Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/69185
Full metadata record
DC FieldValueLanguage
dc.creatorAdriana F.M. Guimarãespt_BR
dc.creatorAline A. C. G. de Souzapt_BR
dc.creatorMaria Cândida Ferrarez Bouzada Vianapt_BR
dc.creatorZilda M. A. Meirapt_BR
dc.date.accessioned2024-06-13T22:34:10Z-
dc.date.available2024-06-13T22:34:10Z-
dc.date.issued2017-
dc.citation.volume93pt_BR
dc.citation.issue2pt_BR
dc.citation.spage172pt_BR
dc.citation.epage178pt_BR
dc.identifier.doihttps://doi.org/10.1016/j.jped.2016.05.004pt_BR
dc.identifier.issn0021-7557pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/69185-
dc.description.abstractObjetivos Avaliar a acurácia da análise simultânea dos três marcos anatômicos radiográficos – diafragma, silhueta cardíaca e corpos vertebrais, na determinação da posição da extremidade distal do cateter venoso umbilical, utilizando ecocardiografia como padrão de referência. Métodos Estudo transversal, observacional, com inclusão prospectiva de dados de todos os neonatos nascidos em uma maternidade pública de referência, entre abril de 2012 e setembro de 2013, submetidos à inserção de cateter venoso umbilical como parte do atendimento clínico. A posição da extremidade distal do cateter, determinada pela análise simultânea dos três marcos anatômicos radiográficos, foi comparada com a posição anatômica obtida pela ecocardiografia e sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e acurácia foram calculados. Resultados Dos 162 recém-nascidos avaliados por ecocardiografia, somente 44 (27,16%) estavam com o cateter em posição ótima, na porção torácica da veia cava inferior ou na junção da veia cava inferior com o átrio direito. Os cateteres foram localizados no átrio esquerdo e septo interatrial em 54 (33,33%), no átrio direito em 26 (16,05%), intra-hepático em 37 (22,84%) e na aorta em um recém-nascido (0,62%). A sensibilidade, especificidade e acurácia da radiografia para detectar cateter na zona alvo foi de 56%, 71% e 67,28%, respectivamente. Conclusão A radiografia anteroposterior de tórax isolada não é capaz de definir com segurança a posição do cateter venoso umbilical. A ecocardiografia permite a visibilização direta da ponta do cateter em relação às estruturas vasculares e, sempre que possível, deve ser considerada para localização do cateter venoso umbilical.pt_BR
dc.description.resumoObjectives To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks – diaphragm, cardiac silhouette, and vertebral bodies – in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. Methods This was a cross-sectional, observational study, with the prospective inclusion of data from all neonates born in a public reference hospital, between April 2012 and September 2013, submitted to umbilical venous catheter insertion as part of their medical care. The position of the catheter distal end, determined by the simultaneous analysis of three radiographic anatomical landmarks, was compared with the anatomical position obtained by echocardiography; sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Results Of the 162 newborns assessed by echocardiography, only 44 (27.16%) had the catheter in optimal position, in the thoracic portion of the inferior vena cava or at the junction of the inferior vena cava with the right atrium. The catheters were located in the left atrium and interatrial septum in 54 (33.33%) newborns, in the right atrium in 26 (16.05%), intra-hepatic in 37 (22.84%), and intra-aortic in-one newborn (0.62%). The sensitivity, specificity and accuracy of the radiography to detect the catheter in the target area were 56%, 71%, and 67.28%, respectively. Conclusion Anteroposterior radiography of the chest alone is not able to safely define the umbilical venous catheter position. Echocardiography allows direct visualization of the catheter tip in relation to vascular structures and, whenever possible, should be considered to identify the location of the umbilical venous catheter.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentMED - DEPARTAMENTO DE PEDIATRIApt_BR
dc.publisher.departmentMEDICINA - FACULDADE DE MEDICINApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofJornal de Pediatriapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectRecém-nascidopt_BR
dc.subjectVeias umbilicaispt_BR
dc.subjectCateterismo venoso centralpt_BR
dc.subjectRadiografia torácicapt_BR
dc.subjectEcocardiografiapt_BR
dc.subject.otherRecém-Nascidopt_BR
dc.subject.otherVeias Umbilicaispt_BR
dc.subject.otherCateterismo Venoso Centralpt_BR
dc.subject.otherRadiografia Torácicapt_BR
dc.subject.otherEcocardiografiapt_BR
dc.titleAccuracy of chest radiography for positioning of the umbilical venous catheterpt_BR
dc.title.alternativeAcurácia da radiografia de tórax para o posicionamento do cateter venoso umbilicalpt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://www.sciencedirect.com/science/article/pii/S0021755716300791?via%3Dihubpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7397-6931pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Accuracy of chest radiography for positioning of the umbilical venous catheter.pdf759.31 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.