Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/69191
Type: Artigo de Periódico
Title: A radiografia do joelho em flexão fixa utilizando um novo posicionador produziu medidas da largura do espaço articular com alta repetibilidade: estudo ELSA‐Brasil Musculoesquelético (ELSA‐Brasil ME)
Other Titles: Fixed‐flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA‐Brasil Musculoskeletal Study (ELSA‐Brasil MSK)
Authors: Rosa Weiss Telles
Luciana Costa‐Silva
Luciana A.C. Machado
Rodrigo Citton Padilha dos Reis
Sandhi Maria Barreto
Abstract: Objetivo: Descrever o desempenho de um protocolo radiográfico em flexão fixa sem fluoroscopia em incidência PA com um novo posicionador, desenvolvido para a avaliação da osteoartrite de joelho (OA) no estudo ELSA‐Brasil ME. Material e métodos: Fez‐se um estudo de teste e reteste que incluiu 19 adultos (38 imagens de joelho). A viabilidade do protocolo radiográfico foi avaliada por meio de parâmetros de qualidade da imagem e presença de alinhamento radioanatômico de acordo com as medidas da distância intermarginal (DIM). Avaliaram‐se a repetibilidade dos valores de DIM e do espaço articular (EA) em três locais diferentes. Resultados: Aproximadamente 90% das imagens de joelho apresentaram uma qualidade excelente. As frequências de imagens com alinhamento radioanatômico quase perfeito (DIM<1mm) variaram de 29% a 50%, e de alinhamento satisfatório (DIM<1,5mm e <1,7mm) de 71% a 76%, respectivamente. As análises de repetibilidade produziram os seguintes resultados: DIM [DP da média das diferenças = 1,08; coeficiente de variação (% CV) = 54,68%; coeficiente de correlação intraclasse (CCI) (IC 95%) = 0,59 (0,34 a 0,77)]; EA [DP da média das diferenças = 0,34 a 0,61; % CV = 4,48% a 9,80%; CCI (IC 95%) = 0,74 (0,55 a 0,85) a 0,94 (0,87 a 0,97]. Encontraram‐se medidas adequadamente reprodutíveis de DIM e EA em 68% e 87% das imagens, respectivamente. Conclusões: Apesar da dificuldade de obter um alinhamento radioanatômico consistente entre radiografias repetidas em termos de DIM, o protocolo produziu medições de EA altamente repetíveis quando essas foram tomadas no ponto médio e a 10 mm da extremidade medial do platô tibial medial. Portanto, as medidas de EA nesses locais podem ser consideradas adequadas para a avaliação da OA de joelho no estudo ELSA‐Brasil ME.
Abstract: Objective: To describe the performance of a non‐fluoroscopic fixed‐flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in ELSA‐Brasil MSK. Material and methods: A test‐retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34‐0.77)]; JSW [SD of mean difference = 0.34 ‐ 0.61; %CV = 4.48% ‐ 9.80%; ICC (95%CI) = 0.74 (0.55‐0.85) ‐ 0.94 (0.87‐0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateu. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA‐Brasil MSK.
Subject: Radiografia
Joelho
Osteoartrite do joelho
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: MED - DEPARTAMENTO DE ANATOMIA E IMAGEM
MED - DEPARTAMENTO DE CLÍNICA MÉDICA
MED - DEPARTAMENTO DE MEDICINA PREVENTIVA SOCIAL
MED - DEPARTAMENTO DE PROPEDÊUTICA COMPLEMENTAR
Rights: Acesso Aberto
metadata.dc.identifier.doi: https://doi.org/10.1016/j.rbr.2016.10.003
URI: http://hdl.handle.net/1843/69191
Issue Date: 2016
metadata.dc.url.externa: https://www.sciencedirect.com/science/article/pii/S0482500416301450?via%3Dihub
metadata.dc.relation.ispartof: Revista Brasileira de Reumatologia