dc.description.abstract | Introdução: Este trabalho objetiva avaliar a segurança do uso do parafuso de trajeto cortical com transfixação da segunda cortical óssea com relação às estruturas vasculares. Métodos: Estudo observacional retrospectivo (nível de evidência: III, estudo de pacientes não consecutivos) analisou dados de prontuários de pacientes submetidos ao exame de angiotomografia computadorizada do abdome no Hospital Mater Dei, realizando a medida, em milímetros, entre o ponto da vértebra lombar considerado a referência anatômica para a transfixação da segunda cortical óssea e as estruturas vasculares adjacentes à coluna (aorta abdominal, veia cava inferior, vasos ilíacos, artérias lombares segmentares). Resultados: Foram avaliados 48 pacientes, com média de idade de 60 anos (±8 anos, 41-75), sendo 52% do sexo masculino e 48% do feminino. As medidas obtidas entre os vasos pré-vertebrais e os pontos possíveis de saída do parafuso não demonstraram contato, em todas as vértebras estudadas. Conclusões: As medidas obtidas sugerem a segurança do uso do parafuso de trajeto cortical transfixando a segunda cortical óssea. Conhecer a posição dos vasos é essencial para reduzir as complicações intra e pós-operatórias relacionadas à instrumentação da coluna vertebral. Nível de evidência III; Estudo de pacientes não consecutivos. | pt_BR |
dc.description.resumo | Introduction: This study aims to evaluate the safety of using the cortical path screw with transfixation of the second cortical bone in relation to the vascular structures. Methods: This retrospective observational study (level of evidence: III, study of non-consecutive patients) analyzed data from the medical records of patients who underwent computed angiotomography scans of the abdomen at Hospital Mater Dei, measuring, in millimeters, the distance between the point of the lumbar vertebra considered the anatomical reference for the transfixation of the second cortical bone and the vascular structures adjacent to the spine (abdominal aorta, inferior vena cava, iliac vessels, segmental lumbar arteries). Results: Forty-eight patients were evaluated, with a mean age of 60 years (±8 years, 41-75), of whom 52% were male and 48% female. The measurements obtained between the pre-vertebral vessels and the possible screw exit points did not demonstrate contact in any of the vertebrae studied. Conclusions: The measurements obtained suggest the safety of using the cortical path screw transfixing the second cortical bone. Knowing the position of the vessels is essential to reduce intra- and postoperative complications related to spinal instrumentation. Level of evidence III; Study of non-consecutive patients. | pt_BR |
dc.format.mimetype | pt_BR | |
dc.language | eng | pt_BR |
dc.publisher | Universidade Federal de Minas Gerais | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.publisher.department | MED - DEPARTAMENTO DE APARELHO LOCOMOTOR | pt_BR |
dc.publisher.initials | UFMG | pt_BR |
dc.relation.ispartof | Coluna/columna | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.subject | Cortical bone | pt_BR |
dc.subject | Spinal fusion | pt_BR |
dc.subject | Manipulation | pt_BR |
dc.subject | Lumbar | pt_BR |
dc.subject | Spinal fractures | pt_BR |
dc.subject.other | Osso cortical | pt_BR |
dc.subject.other | Fusão vertebral | pt_BR |
dc.subject.other | Manipulação da coluna | pt_BR |
dc.subject.other | Fraturas da coluna vertebral | pt_BR |
dc.title | Relationship between vertebral vessels and cortical path screws in cortical transfixation | pt_BR |
dc.title.alternative | Relação dos vasos vertebrais com parafuso de trajeto cortical com transfixação da cortical | pt_BR |
dc.title.alternative | Relación de los vasos vertebrales con tornillo de trayectoria cortical con transfijación cortical | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.url.externa | https://www.scielo.br/j/coluna/a/yXSyLWgsVgXqm3KDB9TqbPv/# | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-4863-9367 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0002-9952-5151 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-1058-3804 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0001-6327-1260 | pt_BR |
Appears in Collections: | Artigo de Periódico |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Relationship between vertebral vessels and cortical path screws in cortical transfixation.pdf | 300.71 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.