Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/71542
Full metadata record
DC FieldValueLanguage
dc.creatorLuiz Paulo Carvalhorochapt_BR
dc.creatorTânia de Carvalho Rochapt_BR
dc.creatorStephanie de Cássia Carvalho Rochapt_BR
dc.creatorPatrícia Valéria Henriquept_BR
dc.creatorFlávio Ricardo Manzipt_BR
dc.creatorMicena Roberta Miranda Alves e Silvapt_BR
dc.date.accessioned2024-07-25T19:52:27Z-
dc.date.available2024-07-25T19:52:27Z-
dc.date.issued2020-
dc.citation.volume50pt_BR
dc.citation.issue2pt_BR
dc.citation.spage175pt_BR
dc.citation.epage180pt_BR
dc.identifier.doihttps://doi.org/10.5624/isd.2020.50.2.175pt_BR
dc.identifier.issn22337822pt_BR
dc.identifier.urihttp://hdl.handle.net/1843/71542-
dc.description.abstractObjetivo: Neste estudo, utilizamos a ultrassonografia para monitorar o uso do ácido hialurônico (AH) como preenchimento facial para razões estéticas. Monitoramos mudanças na forma, distribuição e relação do preenchimento com estruturas anatômicas adjacentes. estruturas durante um período de 180 dias. Materiais e Métodos: Dois pacientes receberam, cada um, uma injeção de AH guiada por ultrassom, com produtos diferentes e locais de aplicação para cada paciente. Em 1 paciente a injeção foi administrada no ângulo da mandíbula, enquanto no outro, foi administrado na região zigomática. Os locais de injeção foram monitorados via ultrassonografia aos 24 horas, 30 dias e 180 dias, momentos em que foram observadas as características de imagem do preenchedor. Todas as injeções foram realizados pelo mesmo profissional, assim como os exames ultrassonográficos, realizados no mesmo equipamento. Resultados: Em ambos os casos, os preenchimentos de AH foram visualizados por ultrassom em todos os momentos. Algumas diferenças foram observado entre os casos nas imagens e a distribuição dos bolsões de preenchimento. Em 1 caso, o preenchimento apareceu como uma região hipoecóica escura com contornos bem definidos, e observou-se que o material se moveu posteriormente por a marca dos 180 dias. No outro caso, o material parecia hiperecóico em relação ao caso anterior e não apresentava mudanças perceptíveis em sua distribuição ântero-posterior ao longo do tempo. Conclusão: Com base nesses 2 casos, a ultrassonografia pode ser uma ferramenta complementar utilizada para monitorar os preenchimentos faciais ao longo do tempo. a longo prazo, permitindo a observação dinâmica de diferentes enchimentos.pt_BR
dc.description.resumoPurpose: In this study, we used ultrasonography to monitor the use of hyaluronic acid (HA) as a filler in the face for esthetic reasons. We monitored changes in the filler shape, distribution, and relationship with adjacent anatomical structures over a 180-day period. Materials and Methods: Two patients each received an ultrasound-guided injection of HA, with different products and application sites for each patient. In 1 patient, the injection was administered in the angle of the mandible, while in the other, it was administered in the zygomatic region. The injection sites were monitored via ultrasonography at 24 hours, 30 days, and 180 days, at which times the imaging characteristics of the filler were observed. All injections were performed by the same professional, as were the ultrasound exams, which were conducted using the same equipment. Results: In both cases, the HA fillers were visualized using ultrasound at all time points. Some differences were observed between the cases in the images and the distribution of the pockets of filler. In 1 case, the filler appeared as a dark hypoechoic region with well-defined contours, and the material was observed to have moved posteriorly by the 180-day mark. In the other case, the material appeared hyperechoic relative to the previous case and presented no noticeable changes in its anteroposterior distribution over time. Conclusion: Based on these 2 cases, ultrasonography can be a complementary tool used to monitor facial fillers over the long term, allowing for the dynamic observation of different fillers.pt_BR
dc.format.mimetypepdfpt_BR
dc.languageengpt_BR
dc.publisherUniversidade Federal de Minas Geraispt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentICB - DEPARTAMENTO DE MORFOLOGIApt_BR
dc.publisher.initialsUFMGpt_BR
dc.relation.ispartofImaging Science in Dentistrypt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectUltrasonographypt_BR
dc.subjectEstheticspt_BR
dc.subjectHyaluronic Acidpt_BR
dc.subjectDermal Fillerspt_BR
dc.subject.otherUltrassonografiapt_BR
dc.subject.otherEstética Dentáriapt_BR
dc.subject.otherÁcido Hialurônicopt_BR
dc.subject.otherPreenchedores Dérmicospt_BR
dc.titleUltrasonography for long-term evaluation of hyaluronic acid filler in the face: A technical report of 180 days of follow-uppt_BR
dc.title.alternativeUltrassonografia para avaliação em longo prazo do preenchimento facial com ácido hialurônico: uma técnica relatório de 180 dias de acompanhamentopt_BR
dc.typeArtigo de Periódicopt_BR
dc.url.externahttps://isdent.org/DOIx.php?id=10.5624/isd.2020.50.2.175pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-6074-5093pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-6541-9281pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-8425-5339pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-9244-6859pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-9467-5137pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-6642-3650pt_BR
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Ultrasonography for long-term evaluation of hyaluronic.pdfA.pdf612.59 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.