Use este identificador para citar ou linkar para este item: http://hdl.handle.net/1843/73654
Tipo: Artigo de Evento
Título: Avaliação do desempenho de módulos fotovoltaicos com mais de 10 anos de exposição em campo
Título(s) alternativo(s): Degradation evaluation of photovoltaic modules more than 10 years of field exposure
Autor(es): Denio Alves Cassini
Antonia Sonia Alves Cardoso
Marcelo Machado Viana
Suellen Caroline Silva Costa
Thiago de Almeida Silvério
Francisco Hering Alves de Freitas Souza
Lawrence Lee Kazmerski
Resumo: Este artigo apresenta os resultados da investigação de perdas de desempenho de módulos fotovoltaicos, bem como a identificação de problemas de falha e durabilidade. Para isso, este trabalho utilizou da coleta de amostras obtidas de aproximadamente 1000 sistemas fotovoltaicos autônomos, composto por sistema fotovoltaico residencial (tamanho 150 Wp) e sistema em escolas (aproximadamente 2000 Wp), que foram instalados e são operados pela Companhia Energética de Minas Gerais-CEMIG. Estes sistemas fotovoltaicos foram implantados no estado de Minas Gerais, e os sistemas mais antigos possuem mais de 10 anos de operação. Os sistemas autônomos estão localizados na região norte e no leste de Minas Gerais. Estas regiões são consideradas como zonas de clima subtropical, com invernos secos e verões chuvosos. Estes sistemas não tinha tido uma avaliação rigorosa de sua confiabilidade e desempenho de operação – investigação de qualquer envelhecimento do módulo ou identificação dos principais mecanismos de degradação. Foram utilizados procedimentos de inspeção visual para identificar os principais modos de degradação nos módulos fotovoltaicos como, descoloração gradual do encapsulamento e delaminação do encapsulante – que podem ser causadas pela elevada incidência de radiação ultravioleta existente, bem como presença de sujidades depositadas sobre os módulos, com até 20% de obscurecimento de transmissão. Este artigo fornece uma análise inicial dos resultados das inspeções visuais de módulos fotovoltaicos, a identificação dos modos de degradação e as medidas tomadas para restaurar os níveis aceitáveis de operação (por exemplo, inspeções regulares e limpezas periódicas programadas). Para a próxima etapa, será abordada uma amostragem mais ampla de módulos, com testes do desempenho elétrico dos mesmos e um estudo estatístico das falhas dos sistemas fotovoltaicos instalados em Minas Gerais.
Abstract: This paper presents the results of the investigation of performance losses ofphotovoltaic moduleand the identification of component failure and durability issues. Therefore, this study used thesample collection obtained of the approximately 1000 stand-alone PV systems, which include solar home systems (sized 150 Wp) and schools systems (approximately 2000 Wp). These were commissioned and are operated by the Energetic Company of Minas Gerais (CEMIG). These PV systems are installed in the state of Minas Gerais, with the oldest 10 years in operation. The stand-alone systems are located at northern and eastern region of Minas Gerais. These areas are considered subtropical climate zones, with dry winters and rainy summers. These systems had not had a rigorous evaluation for their reliability and operation performance—with no reporting of any module ageing or identifying major degradation mechanisms. Following accepted power-plant evaluation methodologies, we used visual inspection procedures to identify the major PV module degradation modes as gradual encapsulant discoloration and delamination—that may be caused by the high incidence of ultraviolet radiationexisting, as well as presence of deposited dirt on the modules, with until 20% obscuration transmission. This paper provides an initial analysis of the visual inspection results of photovoltaic modules, the identification of the degradation modes, and the steps taken to restore acceptable levels of operation (e.g., regular inspections and periodic cleaning schedules).At the next step further degradation will be investigated in a larger sample of modules, with performance electrical test and statistical analysis of the failures of the PV systems installed in Minas Gerais.
Assunto: Energia fotovoltaica
Biodegradação
Desempenho - Avaliação
Idioma: por
País: Brasil
Editor: Universidade Federal de Minas Gerais
Sigla da Instituição: UFMG
Departamento: ICX - DEPARTAMENTO DE QUÍMICA
Tipo de Acesso: Acesso Aberto
Identificador DOI: https://doi.org/10.59627/cbens.2016.1794
URI: http://hdl.handle.net/1843/73654
Data do documento: 2016
metadata.dc.url.externa: https://anaiscbens.emnuvens.com.br/cbens/article/view/1794
metadata.dc.relation.ispartof: Congresso Brasileiro de Energia Solar (CBENS)
Aparece nas coleções:Artigo de Evento