Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/83945
Type: Artigo de Periódico
Title: Acurácia do ecocardiograma transtorácico como método de triagem na prática clínica da investigação da hipertensão pulmonar
Other Titles: Accuracy of Transthoracic Echocardiogram as a Screening Method in the Clinical Practice of Pulmonary Hypertension Investigation
Authors: Camila Farnese Rezende
Eliane Viana Mancuzo
Maria do Carmo Pereira Nunes
Ricardo Amorim Corrêa
Abstract: Fundamento: O ecocardiograma transtorácico (ETT) tem um papel de triagem no algoritmo diagnóstico da hipertensão pulmonar (HP). Estudos demonstraram uma discordância significativa entre as medições do ETT da pressão arterial pulmonar sistólica (PAPs) e da pressão atrial direita (PAD) e as obtidas pelo cateterismo do coração direito (CCD). Objetivo: Comparar as medições do ETT da PAPs e da PAD com as obtidas pelo CCD em pacientes com suspeita de HP. Métodos: Pacientes encaminhados a um centro de referência com probabilidade alta ou intermediária de PH ao ETT na admissão hospitalar passaram por CCD. A concordância entre a PAPs e a PAD em ambos os procedimentos foi avaliada pelo teste de Bland-Altman. Diferenças de até 10 mmHg na PAPs e de até 5 mmHg na PAD foram consideradas dentro da variabilidade do teste. A curva de característica de operação do receptor (ROC) foi construída para determinar os valores mais precisos de PAPs e VRT associados ao diagnóstico de HP pelo CCD. O nível de significância estatística adotado foi 5%. Resultados: Foram incluídos noventa e cinco pacientes. A análise de Bland-Altman análise revelou um viés de 8,03 mmHg (IC 95%: -34,9 a 50,9) na PAPs e -3,30 mmHg (IC 95%: -15,9 a 9,3) na PAD. AUC da PAPs e VRT medidas pelo ETT para a discriminação de provável HP foram de 0,936 (IC 95%: 0,836 a 1,0) e 0,919 (IC 95%: 0,837 a 1,0), respectivamente. Entretanto, apenas 33,4% da estimativa ecocardiográfica da PAPs e 55,1% da PAD foram precisas, em comparação às medições obtidas pelo CCD. Conclusão: O ETT tem um alto poder discriminatório como método diagnóstico de triagem para HP, apesar de apresentar discordâncias entre os valores absolutos de PAPs e PAD, em comparação às medições por CCD.
Abstract: Background: The transthoracic echocardiogram (TTE) plays a screening role in the diagnostic algorithm of pulmonary hypertension (PH). Studies have shown a significant disagreement between TTE measurements of the systolic pulmonary artery pressure (sPAP) and right atrial pressure (RAP) and those obtained by right heart catheterization (RHC). Objective: To compare TTE measurements of sPAP and RAP with those obtained by RHC in patients being investigated for PH. Methods: Patients referred to a PH reference center with a high or intermediate TTE probability of PH upon admission were submitted to RHC. The agreement between sPAP and RAP from both procedures was assessed through the Bland-Altman test. Differences of up to 10 mmHg for sPAP and 5 mmHg for RAP were considered within the variability of the test. Receiver Operating Characteristic (ROC) curve was constructed to determine the most accurate sPAP and TRV values associated with the diagnosis of PH by RHC. The adopted level of statistical significance was 5%. Results: Ninety-five patients were included. The Bland-Altman analysis showed a bias of 8.03 mmHg (95% CI:-34.9-50.9) for sPAP and -3.30 mmHg (95% CI:-15.9 to 9.3) for RAP. AUC for sPAP and TRV measured by TTE for discrimination of probable PH were 0.936 (95% CI: 0.836-1.0) and 0.919 (95% CI: 0.837-1.0), respectively. However, only 33.4% of the echocardiographic estimate of sPAP and 55.1% of RAP were accurate, as compared to the measurements obtained by RHC.
Subject: Ecocardiografia
Hipertensão Pulmonar
Confiabilidade dos Dados
language: por
metadata.dc.publisher.country: Brasil
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
metadata.dc.publisher.department: MED - DEPARTAMENTO DE CLÍNICA MÉDICA
Rights: Acesso Aberto
metadata.dc.identifier.doi: 10.36660/abc.20220461
URI: http://hdl.handle.net/1843/83945
Issue Date: 2023
metadata.dc.url.externa: https://doi.org/10.36660/abc.20220461
Appears in Collections:Artigo de Periódico

Files in This Item:
File Description SizeFormat 
Acurácia do Ecocardiograma Transtorácico pdfa.pdf434.63 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.