Please use this identifier to cite or link to this item: http://hdl.handle.net/1843/BUOS-8BZG64
Type: Dissertação de Mestrado
Title: Avaliação da imunofluorescência direta no diagnóstico da campilobacteriose genital bovina
Authors: Josely Ferreira Figueiredo
First Advisor: Andrey Pereira Lage
First Referee: Romulo Cerqueira Leite
Second Referee: Zelia Ines Portela Lobato
Third Referee: Isabella Bias Fortes Ferraz
Abstract: O teste de imunofluorescência direta para diagnóstico da Campilobacteriose Genital Bovina foi avaliado quanto ao limite de detecção, efeito dos observadores e sensibilidade e especificidade. Além disso, a especificidade do conjugado fluorescente foi testada contra Campylobacter SP. Arcobacter SP. Helicohacter SP. E. coli e bactérias da flora normal do precúcio. Foram usadas dez diluições na base 10 de C. fetus subsp. Venerealis NCTC 10354 em PBS ou em lavado prepucial centrifugado e não centrifugado. Todo experimento foi feito às cegas, em duplicata, com controles positivos e negativos e com três observadores. Os limites de detecção da imunofluorescência direta foram 104, 104 e 102 UFC/ml. Respectivamente, em PBS, lavado prepucial não centrifugado e centrifugado. Não houve diferenças significativa entre as leituras dos observadores. A técnica apresentou especificidade de 88,89% e sensibilidade de 92,59%. O conjugado fluorescente reconheceu somente C. fetus. A imunofluorescência direta para C. fetus subsp. Veneralis mostrou-se especifica sensível e não foi influenciada pelos observadores.
Abstract: The direct immunofluorescence test for the diagnosis of Bovine Genital Campylobacteriosis was evaluated for detection limit, effect of observers, sensitivity and specificity. Furthermore, the specificity of the fluorescent conjugate was tested against Campylobacter SP. Arcobacter SP. Helicohacter SP. E. coli bacteria and normal flora of precúcio. Ten dilutions were used at the base of 10 C. fetus subsp. Venerealis NCTC 10354 or washed in PBS and centrifuged preputial not centrifuged. Every experiment was done blindly, in duplicate, with positive and negative controls and three observers. The detection limits of direct immunofluorescence were 104, 104 and 102 CFU / ml. Respectively, in PBS, centrifuged and washed preputial not centrifuged. There were no significant differences between the readings of the observers. The technique had a specificity of 88.89% and sensitivity of 92.59%. The fluorescent conjugate recognized only C. fetus. Direct immunofluorescence for C. fetus subsp. Veneralia proved to be sensitive and specific was not influenced by the observers
Subject: Bovino Doenças
Infecções por campylobacter
Imunofluorescência
language: Português
Publisher: Universidade Federal de Minas Gerais
Publisher Initials: UFMG
Rights: Acesso Aberto
URI: http://hdl.handle.net/1843/BUOS-8BZG64
Issue Date: 22-Mar-2001
Appears in Collections:Dissertações de Mestrado

Files in This Item:
File Description SizeFormat 
disserta__o_de_mestrado_de_josely_ferreira_figueiredo.pdf6.53 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.