Use este identificador para citar o ir al link de este elemento: http://hdl.handle.net/1843/BUOS-9LFJC4
Tipo: Monografias de Especialização
Título: Avaliação da eficácia do Root ZX II e Novapex na localização do forame apical realizada por dois operadores distintos e comparada com radiografia digital
Autor(es): Liliane de Oliveira Ramos
primer Tutor: Katia Lucy de Melo Maltos
primer Co-tutor: Sandra Maria de Melo Maltos
primer miembro del tribunal : Juliana Vilela Bastos
Segundo miembro del tribunal: Maria Ilma de Souza Gruppioni Cortes
Resumen: No tratamento endodôntico, a determinação do comprimento de trabalho é de fundamental importância para que seja alcançada a instrumentação e obturação adequadas do sistema de canais radiculares. O propósito deste estudo foi avaliar, in vitro, a eficácia dos localizadores eletrônicos de forame apical (LEFAs) Root ZX II e Novapex, bem como a influência do operador, e ainda, fazer uma análise das imagens radiográficas digitais, orto-radial e angulada, das medidas obtidas. O trabalho foi aprovado pelo COEP/Plataforma Brasil (protocolo 30236614.2.0000.5149). Radiografias digitais de estudo, abertura coronária e comprovação da patência foraminal com microscópio cirúrgico (medida real) foram realizadas em 31 dentes humanos extraídos. As medições com os aparelhos Root ZX II e Novapex foram feitas por dois operadores distintos e considerou-se acerto quando coincidentes com a medida real (MR). As medidas de acerto encontradas foram: operador I - 36,1% Root ZX II, 27,8% Novapex; operador II - 33,3% Root ZX II, 25% Novapex. Em mais de 50% dos casos as imagens radiográficas foram capazes de mostrar os acertos ou erros das medidas obtidas pelos LEFAs. Concluiu-se que os LEFAs Root ZX II e Novapex falharam na determinação da MR na maioria dos canais radiculares avaliados, para ambos os operadores, o que poderia ser minimizado com a associação da técnica radiográfica.
Abstract: Determining the working length is crucial for the appropriate instrumentation and obturation of the root canal system in endodontic treatment. The purpose of this study was to evaluate, in vitro, the efficacy of electronic foramen apical locators - Root ZX II and Novapex, as well as the influence of the operator and also, analyze ortho-radial and angled radiographic digital images, of the measurements obtained. The study was approved by COEP/Plataforma Brasil (protocol 30236614.2.0000.5149). Digital radiography study, coronary opening and proof of foraminal patency with surgical microscope (real measurement) were performed on 31 extracted human teeth. Measurements using Root ZX II and Novapex were made by two different operators and it was considered right when matching with the real measurement as in the following: operator I - Root ZX II 36.1%, Novapex 27.8%; operator II - Root ZX II 33.3%, Novapex 25%. In over 50% of cases the radiographic images were able to determine, either the correct measurements or errors of the electronic locators. It was concluded that Root ZX II and Novapex failed in determining the real measurement of the most root canals, for both operators, which could be minimized with the association of radiographic technique.
Asunto: Odontometria
Canal radicular Tratamento
Ápice dentário
Radiografia dentária digital/utilização
Preparo do canal radicular/métodos
Instrumentos odontológicos
Cavidade pulpar/radiografia
Idioma: Português
Editor: Universidade Federal de Minas Gerais
Sigla da Institución: UFMG
Tipo de acceso: Acesso Aberto
URI: http://hdl.handle.net/1843/BUOS-9LFJC4
Fecha del documento: 11-jun-2014
Aparece en las colecciones:Especialização em Endodontia

archivos asociados a este elemento:
archivo Descripción TamañoFormato 
monografia_liliane_de_oliveira_ramos.pdf1.23 MBAdobe PDFVisualizar/Abrir


Los elementos en el repositorio están protegidos por copyright, con todos los derechos reservados, salvo cuando es indicado lo contrario.