Acute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load
| dc.creator | Marcel Bahia Lanza | |
| dc.creator | Antônio Eustáquio de Melo Pertence | |
| dc.creator | André G. P. Andrade | |
| dc.creator | Gustavo Henrique da Cunha Peixoto Cançado | |
| dc.creator | Leonardo Bonato | |
| dc.creator | Mauro H. Chagas | |
| dc.date.accessioned | 2024-01-31T16:10:12Z | |
| dc.date.accessioned | 2025-09-08T23:53:14Z | |
| dc.date.available | 2024-01-31T16:10:12Z | |
| dc.date.issued | 2017 | |
| dc.description.abstract | O objetivo deste estudo foi propor um dispositivo mecânico que acoplado a uma cadeira flexora aumente a carga mecânica durante toda a ação excêntrica (ECC) e comparar a atividade muscular durante a utilização do dispositivo proposto. Quinze mulheres fisicamente ativas foram recrutadas e realizaram dois diferentes protocolos (controle e sobrecarga ECC). O protocolo controle foi realizado com ações concêntricas (CON) e ECC com carga iguais (60% de uma repetição máxima), enquanto o protocolo de sobrecarga ECC consistiu em ações ECC com 40% mais de carga do que as ações CON. A ativação muscular dos músculos biceps femoris (BF) e gastrocnemius medialis (GM) foi medida por meio de eletromiografia de superfície. Durante as ações ECC foi observada uma maior ativação do BF durante o protocolo de sobrecarga quando comparado ao protocolo controle (p = 0,032). No entanto, GM não apresentou diferenças na ativação entre os protocolos (p = 0,439). O dispositivo mecânico proposto foi capaz de aumentar a carga durante a ação ECC e, consequentemente, a atividade muscular do BF. | |
| dc.description.sponsorship | FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais | |
| dc.description.sponsorship | CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior | |
| dc.description.sponsorship | Outra Agência | |
| dc.identifier.doi | https://doi.org/10.5007/1980-00372017v19n4p375 | |
| dc.identifier.issn | 1980-0037 | |
| dc.identifier.uri | https://hdl.handle.net/1843/63555 | |
| dc.language | eng | |
| dc.publisher | Universidade Federal de Minas Gerais | |
| dc.relation.ispartof | Revista brasileira de cineantropometria & desempenho humano | |
| dc.rights | Acesso Aberto | |
| dc.subject | Contração muscular | |
| dc.subject | Eletromiografia | |
| dc.subject | Treino aeróbico | |
| dc.subject.other | Electromyography | |
| dc.subject.other | Muscle contraction | |
| dc.subject.other | Resistance training | |
| dc.title | Acute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load | |
| dc.title.alternative | Resposta neuromuscular aguda durante protocolo de sobrecarga excêntrica utilizando dispositivo mecânico para aumento de carga | |
| dc.type | Artigo de periódico | |
| local.citation.epage | 384 | |
| local.citation.issue | 4 | |
| local.citation.spage | 375 | |
| local.citation.volume | 19 | |
| local.description.resumo | The aim of this study was to propose a mechanical device that could increase the mechanical load during the entire eccentric (ECC) action on a knee flexor machine and to compare the muscular activity when the device was used during a testing protocol. Fifteen physically active women were recruited, and they performed two protocols: control and eccentric overload. Control protocol was performed with concentric (CON) and ECC actions with similar load (60% of one repetition maximum) whilst eccentric overload protocol consisted of ECC actions with 40% more load than CON actions. Muscular activation was measured using surface electromyography of the biceps femoris (BF) and the gastrocnemius medialis (GM) muscles. ECC actions presented a higher muscular activation during eccentric overload protocol than control protocol for BF (p = 0.032), but not for the GM (p = 0.439). The mechanical device increased the mechanical load during the ECC muscle action and consequently increased the amplitude of the neural drive to the BF muscle; however, it did not increase the amplitude of the neural drive to the GM muscle. | |
| local.identifier.orcid | https://orcid.org/0000-0002-9898-3070 | |
| local.identifier.orcid | https://orcid.org/0000-0002-7024-3505 | |
| local.identifier.orcid | https://orcid.org/0000-0002-6184-2354 | |
| local.identifier.orcid | https://orcid.org/0000-0002-1955-8990 | |
| local.publisher.country | Brasil | |
| local.publisher.department | EEF - DEPARTAMENTO DE ESPORTES | |
| local.publisher.initials | UFMG | |
| local.url.externa | https://www.scielo.br/j/rbcdh/a/GbYwttCnwmZQqJ3rLpSyGZG/?lang=en# |
Arquivos
Pacote original
1 - 1 de 1
Carregando...
- Nome:
- Acute neuromuscular response during eccentric overload protocol by using a mechanical device to increase the load.pdf
- Tamanho:
- 270.9 KB
- Formato:
- Adobe Portable Document Format
Licença do pacote
1 - 1 de 1