Spatial resolution of a preclinical PET tomograph

dc.creatorGuilherme Cavalcante de Albuquerque Souza
dc.creatorRodrigo Modesto Gadelha Gontijo
dc.creatorJuliana Batista da Silva
dc.creatorMarcelo Mamede
dc.creatorAndréa Vidal Ferreira
dc.date.accessioned2023-08-02T20:46:52Z
dc.date.accessioned2025-09-08T22:49:49Z
dc.date.available2023-08-02T20:46:52Z
dc.date.issued2021
dc.format.mimetypepdf
dc.identifier.doi10.15392/bjrs.v9i1a.1503
dc.identifier.issn23190612
dc.identifier.urihttps://hdl.handle.net/1843/57384
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofBrazilian Journal of Radiation Sciences
dc.rightsAcesso Aberto
dc.subjectTomografia por Emissão de Pósitrons
dc.subjectDiagnóstico por Imagem
dc.subject.otherSPATIAL RESOLUTION
dc.subject.otherSMALL ANIMAL PET SCANNER
dc.subject.otherIMAGE QUALITY CONTROL
dc.titleSpatial resolution of a preclinical PET tomograph
dc.typeArtigo de periódico
local.citation.epage18
local.citation.issue1A
local.citation.spage01
local.citation.volume9
local.description.resumoPositron emission tomography (PET) is an important molecular image modality and its application in preclinical research has increased during the last decades. Thus, in laboratory practice, it is important to implement a quality control of the equipment, since intrinsic factors influence the image quality. The objective of this work was to perform and implement spatial resolution tests for the small animal PET scanner of the Molecular Imaging Laboratory, LIM/CDTN. Empirically, the spatial resolution of a PET scanner can be determined from the measurement of point or linear sources and FWHM (full width half maximum) analysis of the PET image. In this work, a point source of 22Na and a hot rod style phantom filled with the 18F-FDG solution were used. Acquisition and reconstruction of images were performed with the LabPET 1.12.1 software, provided by the equipment manufacturer. PeakFit® and Amide software were used to perform images post-processing. The results indicate that the PET scanner spatial resolution value is compatible with values reported in an international study performed on similar equipment.
local.identifier.orcid0000-0001-6479-3087
local.publisher.countryBrasil
local.publisher.departmentMEDICINA - FACULDADE DE MEDICINA
local.publisher.initialsUFMG
local.url.externahttps://www.bjrs.org.br/revista/index.php/REVISTA/article/view/1503

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Spatial resolution of a preclinical PET tomograph pdfa.pdf
Tamanho:
617.42 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: