Methods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors

dc.creatorAlair Dias Júnior
dc.creatorSrinivasan Murali
dc.creatorFrancisco Rincon
dc.creatorDavid Atienza
dc.date.accessioned2025-03-26T14:10:26Z
dc.date.accessioned2025-09-09T00:48:17Z
dc.date.available2025-03-26T14:10:26Z
dc.date.issued2016
dc.identifier.doi10.1016/j.micpro.2016.06.001
dc.identifier.issn0141-9331
dc.identifier.urihttps://hdl.handle.net/1843/80937
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofMicroprocessors and Microsystems
dc.rightsAcesso Restrito
dc.subjectEstudos transversais DeCS
dc.subjectPressão arterial DeCS
dc.subject.otherPulse transit time, Arterial blood pressure, Smartphone usage, Bio-medical signal processing
dc.titleMethods for reliable estimation of pulse transit time and blood pressure variations using smartphone sensors
dc.typeArtigo de periódico
local.citation.epage95
local.citation.issueA
local.citation.spage84
local.citation.volume46
local.description.resumoHypertension is known to affect around one third of adults globally and early diagnosis is essential to reduce the effects of this affliction. Today’s Blood Pressure (BP) monitoring cuffs are obtrusive and inconvenient for performing regular measurements, and continuous non-invasive blood pressure devices are too complex and expensive for ambulatory use. Hence, there is a strong need for affordable systems that can measure blood pressure (BP) variations throughout the day as this will allow to monitor, diagnose and follow-up not only patients at risk, but also healthy population in general for early diagnosis. A promising method for arterial BP estimation is to measure the Pulse Transit Time (PTT) and derive pressure values from it. However, current methods for measuring this surrogate marker of BP require complex sensing and analysis circuitry and the related medical devices are expensive and inconvenient for the user. In this paper, we present new methods to estimate PTT reliably and subsequently BP, from the baseline sensors of smartphones. This new approach involves determining PTT by simultaneously measuring the time the blood leaves the heart, by recording the heart sound using the standard microphone of the phone, and the time it reaches the finger, by measuring the pulse wave using the phone’s camera. We present algorithms that can be executed directly on current smartphones to obtain clean and robust heart sound signals and to extract the pulse wave characteristics. We also present methods to ensure a synchronous capture of the waveforms, which is essential to obtain reliable PTT values with inexpensive sensors. Additionally, we combine Autocorrelation and Fast Fourier Transform (FFT)-based methods for reliably estimating the user heart rate (HR) from his/her heart sounds, and describe how to use the calculate HR to compensate for the camera frame rate variations and to improve the robustness of PTT estimation. Our experiments show that the computational overhead of the proposed processing methods is minimum, which allows real-time feedback to the user, and that the PTT values are fully accurate (beat-to-beat), thereby enabling state-of-the-art smartphones to be used as affordable medical devices.
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA ELETRÔNICA
local.publisher.initialsUFMG
local.url.externahttps://www.sciencedirect.com/science/article/pii/S0141933116300667

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: