Easy and fast extraction methods to determine organochlorine pesticides in sewage sludge, soil, and water samples based at low temperature

dc.creatorTayane Cristiele Rodrigues Mesquita
dc.creatorRízia Rodrigues Santos
dc.creatorAne Patrícia Cacique
dc.creatorLudimara Jéssica de sá
dc.creatorFlaviano Oliveira Silvério
dc.creatorGevany Paulino de Pinho
dc.date.accessioned2023-01-09T11:35:08Z
dc.date.accessioned2025-09-09T00:05:47Z
dc.date.available2023-01-09T11:35:08Z
dc.date.issued2017-09-14
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais
dc.description.sponsorshipOutra Agência
dc.identifier.doihttps://doi.org/10.1080/03601234.2017.1405626
dc.identifier.issn1532-4109
dc.identifier.urihttps://hdl.handle.net/1843/48776
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofJournal of Environmental Science and Health, Part B
dc.rightsAcesso Aberto
dc.subjectPesticidas - Aspectos ambientais
dc.subjectLodo de esgoto
dc.subjectPoluentes
dc.subjectToxicologia ambiental
dc.subjectSolos - Lixiviação
dc.titleEasy and fast extraction methods to determine organochlorine pesticides in sewage sludge, soil, and water samples based at low temperature
dc.typeArtigo de periódico
local.citation.epage206
local.citation.issue3
local.citation.spage199
local.citation.volume53
local.description.resumoOrganochlorine pesticides present in sewage sludge can contaminate soil and water when they are used as either fertilizer or agricultural soil conditioner. In this study, the technique solid–liquid extraction with low temperature purification was optimized and validated for determination of ten organochlorine pesticides in sewage sludge and soil samples. Liquid–liquid extraction with low temperature purification was also validated for the same compounds in water. Analyses were performed by gas chromatography-mass spectrometry operating in the selective ion monitoring mode. After optimization, the methods showed recoveries between 70% and 115% with relative standard deviation lower than 13% for all target analytes in the three matrices. The linearity was demonstrated in the range of 20 to 70 µg L−1, 0.5 to 60 µg L−1, and 3 to 13 µg L−1, for sludge, soil, and acetonitrile, respectively. The limit of quantification ranged between 2 and 40 µg kg−1, 1 and 6 µg kg−1, and 0.5 µg L−1 for sludge, soil, and water, respectively. The methods were used in the study of pesticide lixiviation carried out in a poly vinyl chlorine column filled with soil, which had its surface layer mixed with sludge. The results showed that pesticides are not leached into soil, part of them is adsorbed by the sewage sludge (4–40%), and most pesticides are lost by volatilization.
local.publisher.countryBrasil
local.publisher.departmentICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS
local.publisher.initialsUFMG
local.url.externahttps://www.tandfonline.com/doi/full/10.1080/03601234.2017.1405626

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Easy and fast extraction methods to determine organochlorine pesticides in sewage sludge soil and water samples based at low temperature.pdf
Tamanho:
947.64 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: