Comparison of torque expression in esthetic brackets

dc.creatorKarine Martelli
dc.creatorKarina Maria Salvatore de Freitas
dc.creatorPatrícia de Oliveira Negreiros
dc.creatorRodrigo Hermont Cançado
dc.creatorFabricio Pinelli Valarelli
dc.creatorMarcos Roberto de Freitas
dc.creatorGuilherme Janson
dc.date.accessioned2023-02-24T14:28:19Z
dc.date.accessioned2025-09-08T23:06:21Z
dc.date.available2023-02-24T14:28:19Z
dc.date.issued2019
dc.identifier.doi10.4317/jced.56102
dc.identifier.issn19895488
dc.identifier.urihttps://hdl.handle.net/1843/50363
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofJournal of Clinical and Experimental Dentistry
dc.rightsAcesso Aberto
dc.subjectOrthodontic brackets
dc.subjectIncisor
dc.subjectCeramics
dc.subjectOrthodontic appliances
dc.subjectTorque
dc.subject.otherTorque
dc.subject.otherOrthodontic brackets
dc.subject.otherOrthodontic Appliances
dc.subject.otherIncisor
dc.subject.otherCeramics
dc.titleComparison of torque expression in esthetic brackets
dc.typeArtigo de periódico
local.citation.epagee789
local.citation.issue9
local.citation.spagee783
local.description.resumoBackground: The objective of this work is to test the null hypothesis that there is no difference in the torque expres sion among different esthetic brackets. Material and Methods: Five ceramic self-ligating brackets (In-Ovation C – GAC, Damon Clear–Ormco, Quic Klear-Forestadent, Click-It -TP Orthodontics, Clarity SL-3M Unitek) and 4 ceramic conventional brackets (Inspi re Ice–Ormco, InVu Ceramic-TP Orthodontics, Ceramic Roth–Morelli, Clarity Metal-Reinforced Ceramic Brac ket-3M Unitek) were selected. Metallic Damon MX self-ligating bracket (Ormco) was used as control. Third-order moments were measured at 12º, 24º and 36º using an archwire torsion device associated with a Universal Testing Machine (EMIC DL2000), with 0.019x0.025-inch stainless steel wire. Anova followed by Tukey tests were used for intergroup comparisons. Results: In all tested angulations the Damon Clear bracket presented the highest torque expression, followed by Clarity, Clarity SL and Damon Mx brackets, with the worst torque expression shown by the InVu Ceramic bracket. The InVu Ceramic demonstrated the largest while the Damon Clear brackets demonstrated the smallest slot height and clearance. Conclusions: The null hypothesis was rejected since torque expression was different among the esthetic brackets evaluated. It was also concluded that the slot height is directly related to torque expression.
local.publisher.countryBrasil
local.publisher.departmentFAO - DEPARTAMENTO DE ODONTOLOGIA RESTAURADORA
local.publisher.departmentFAO - DEPARTAMENTO DE ODONTOPEDIATRIA E ORTODONTIA
local.publisher.initialsUFMG
local.url.externahttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6797454/

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Comparison of torque expression in esthetic brackets.pdf
Tamanho:
831.4 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: