Optimization and validation of LLE-LTP and QuEChERS Methodologies for determining 2,4-D in water samples

dc.creatorLucas Victor Pereira de Freitas
dc.creatorLázaro Chaves Sicupira
dc.creatorGevany Paulino de Pinho
dc.creatorFlaviano Oliveira Silvério
dc.date.accessioned2023-01-11T11:24:51Z
dc.date.accessioned2025-09-09T00:42:34Z
dc.date.available2023-01-11T11:24:51Z
dc.date.issued2020-09
dc.description.sponsorshipCNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
dc.description.sponsorshipOutra Agência
dc.identifier.doihttps://doi.org/10.21577/0103-5053.20200086
dc.identifier.issn1678-4790
dc.identifier.urihttps://hdl.handle.net/1843/48848
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.rightsAcesso Aberto
dc.subjectHerbicidas
dc.subjectResíduos herbicidas
dc.subjectProdutos químicos agrícolas
dc.titleOptimization and validation of LLE-LTP and QuEChERS Methodologies for determining 2,4-D in water samples
dc.typeArtigo de periódico
local.citation.epage1907
local.citation.issue9
local.citation.spage1898
local.citation.volume31
local.description.resumo2,4-Dichlorophenoxyacetic acid (2,4-D) has been one of the main herbicides used to control weeds, however, due to its high use it can promote episodes of environmental contamination. Therefore, this study aimed to optimize and validate the liquid-liquid extraction with low-temperature partition (LLE-LTP) and the quick, easy, cheap, effective, rugged, and safe (QuEChERS) methods for determining 2,4-D in water samples by high performance liquid chromatography with diode array detector. The recovery percentages of the two methodologies were close to 100 ± 3%, and the limits of quantification were 2.0 and 3.1 µg L-1 for LLE-LTP and QuEChERS, respectively. The methodologies were selective and presented linearity from 2.0-26.0 and 3.1-40.6 µg L-1 for LLE-LTP and QuEChERS, respectively. The LLE-LTP was better than QuEChERS due to a smaller number of steps, lower reagent consumption, higher concentration factor and a lower limit of quantification. The real samples did not reveal any environmental contamination episodes by 2,4-D.
local.publisher.countryBrasil
local.publisher.departmentICA - INSTITUTO DE CIÊNCIAS AGRÁRIAS
local.publisher.initialsUFMG
local.url.externahttps://www.scielo.br/j/jbchs/a/LypXFNcsfQX9MpJ8yzDf4Xr/abstract/?lang=en

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Optimization and Validation of LLE-LTP and QuEChERS Methodologies for Determining 2,4-D in Water Samples.pdf
Tamanho:
236.62 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: