Estudo comparativo de um ar condicionado convencional utilizando um fluido refrigerante alternativo ao R-410A para aplicação em escritórios

dc.creatorLeonardo Victor Silva Martins
dc.creatorTiago de Freitas Paulino
dc.creatorRamon de Paoli Mendes
dc.creatorLuiz Machado
dc.creatorWillian Moreira Duarte
dc.date.accessioned2023-08-05T00:31:54Z
dc.date.accessioned2025-09-08T22:57:47Z
dc.date.available2023-08-05T00:31:54Z
dc.date.issued2023-04-05
dc.description.abstractThere is a global schedule to reduce/ban various refrigerants, due to environmental impacts. There is a global schedule to reduce/ban various refrigerants, due to environmental impacts.However, most refrigeration and air conditioning units in developing countries, such as Brazil, operate with R22. In order to reuse this equipment, it is interesting to evaluate alternative fluids that, with some modifications in the system, make it possible to reuse them. As a result, this work compared the COP during one year of a split-type air conditioning system using R-410A and R-290, as well as TEWI for both fluids. For this, a mathematical model developed in the Equation Engineering Solver (EES) was used, encompassing the system components and the thermal zone. Additionally, climatic variations and their impacts on the evaluated enclosure were also considered. Through this study, it was possible to verify that R-290, when compared to R410A, presented, on average, a 44% higher COP, with a 45% lower refrigerant charge, in addition to a 77% lower TEWI. These values suggest that, from the point of view of performance and environmental impact (TEWI), R-290 is a very interesting alternative to R-410A as a replacement for these existing equipment and even for new systems. However, most refrigeration and air conditioning units in developing countries, such as Brazil, operate with R22. In order to reuse this equipment, it is interesting to evaluate alternative fluids that, with some modifications in the system, make it possible to reuse them. As a result, this work compared the COP during one year of a split-type air conditioning system using R-410A and R-290, as well as TEWI for both fluids. For this, a mathematical model developed in the Equation Engineering Solver (EES) was used, encompassing the system components and the thermal zone. Additionally, climatic variations and their impacts on the evaluated enclosure were also considered. Through this study, it was possible to verify that R-290, when compared to R410A, presented, on average, a 44% higher COP, with a 45% lower refrigerant charge, in addition to a 77% lower TEWI. These values suggest that, from the point of view of performance and environmental impact (TEWI), R-290 is a very interesting alternative to R-410A as a replacement for these existing equipment and even for new systems.
dc.format.mimetypepdf
dc.identifier.doihttp://dx.doi.org/10.29327/xxiiconemi.563616
dc.identifier.issn2764-4294
dc.identifier.urihttps://hdl.handle.net/1843/57501
dc.languagepor
dc.publisherUniversidade Federal de Minas Gerais
dc.rightsAcesso Aberto
dc.subjectEngenharia mecânica
dc.subjectModelos matemáticos
dc.subjectAr condicionado
dc.subject.otherR-290,
dc.subject.otherR-410A
dc.subject.otherModelo matemático
dc.subject.otherAr condicionado
dc.titleEstudo comparativo de um ar condicionado convencional utilizando um fluido refrigerante alternativo ao R-410A para aplicação em escritórios
dc.title.alternativeComparative study of a conventional air conditioner using different refrigerant as an alternative for R-410A
dc.typeArtigo de evento
local.citation.epage19
local.citation.issue22
local.citation.spage1
local.description.resumoHá um cronograma global para redução/banimento de diversos fluidos refrigerantes, em função de impactos ambientais. Entretanto, grande parte das unidades de refrigeração e climatização em países em desenvolvimento, como o Brasil, operam com o R-22. Com o intuito de reaproveitar esses equipamentos, é interessante avaliar fluidos alternativos que, com algumas modificações no sistema, possibilitem reaproveitalos. Em função disso, este trabalho comparou o COP durante um ano de um sistema de ar condicionado do tipo split utilizando o R-410A e o R-290, bem como o TEWI para ambos os fluidos. Para isso, foi utilizado um modelo matemático desenvolvido no Equation Engineering Solver (EES), englobando os componentes do sistema e a zona térmica. Adicionalmente, foram consideradas também as variações climáticas e os seus impactos nesse recinto avaliado. Por meio desse estudo, foi possível constatar que o R-290, quando comparado ao R-410A apresentou, em média, um COP 44% maior, com uma carga de refrigerante 45% menor, além de um TEWI 77% menor. Esses valores sugerem que, analisando do ponto de vista de desempenho e impacto ambiental (TEWI), o R-290 é uma alternativa bem interessante para o R-410A como substituto nesses equipamentos já existentes e mesmo para novos sistemas.
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA MECÂNICA
local.publisher.initialsUFMG
local.url.externahttp://dx.doi.org/10.29327/xxiiconemi.563616

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ESTUDO COMPARATIVO DE UM AR CONDICIONADO CONVENCIONAL UTILIZANDO UM FLUIDO - PDFA.pdf
Tamanho:
1.18 MB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.07 KB
Formato:
Plain Text
Descrição: