Normalized spectral responsivity measurement of photodiode by direct method using a supercontinuum laser source

dc.creatorFabiano Sanches Rocha
dc.creatorLuciana Pedrosa Salles
dc.creatorAdo Jorio de Vasconcelos
dc.date.accessioned2022-07-28T12:29:53Z
dc.date.accessioned2025-09-09T00:53:20Z
dc.date.available2022-07-28T12:29:53Z
dc.date.issued2019
dc.description.sponsorshipFAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
dc.identifier.doihttps://doi.org/10.1109/INSCIT.2019.8868527
dc.identifier.isbn978-1-7281-2109-3
dc.identifier.urihttps://hdl.handle.net/1843/43744
dc.languageeng
dc.publisherUniversidade Federal de Minas Gerais
dc.relation.ispartofInternational Symposium on Instrumentation Systems, Circuits and Transducers - INSCIT
dc.rightsAcesso Restrito
dc.subjectÓptica
dc.subjectInstrumentos ópticos
dc.subjectLaser
dc.subject.otherPhotodiode
dc.subject.otherExperimental characterization
dc.subject.otherOptical instrumentation
dc.subject.otherLaser
dc.titleNormalized spectral responsivity measurement of photodiode by direct method using a supercontinuum laser source
dc.typeArtigo de evento
local.citation.epage5
local.citation.issue4
local.citation.spage1
local.description.resumoLight detectors such as photodiodes and phototransistors are fundamental elements that compose imaging sensors and cameras devices. The photocurrent generated by photodiodes depends on the energy of light that is absorbed by semiconductor material, describing an important characteristic of this kind device. We present an optic instrumentation for measurement of normalized spectral responsivity of light detectors. The optics is composed by a single-grating monochromator, converting lens, a slit and a beamsplitter. Supercontinuum lasers provides a high-stability beam with ultra-broadband white-light spectrum. High spectral purity is achieved with only monochromator and the measurements are performed in terms of spectral power measured through a calibrated spectrometer. Uncertainties are examined at carefully for a specific confidence level considering Type A and Type B evaluations.
local.identifier.orcidhttps://orcid.org/0000-0002-5978-2735
local.publisher.countryBrasil
local.publisher.departmentENG - DEPARTAMENTO DE ENGENHARIA ELÉTRICA
local.publisher.departmentICX - DEPARTAMENTO DE FÍSICA
local.publisher.initialsUFMG
local.url.externahttps://ieeexplore.ieee.org/document/8868527/authors#authors

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
License.txt
Tamanho:
1.99 KB
Formato:
Plain Text
Descrição: